810777
50
Zoom out
Zoom in
Previous page
1/210
Next page
- 50 -
ENGLISH
POSSIBLE TROUBLESHOOTINGPOSSIBLE TROUBLESHOOTING
In the event of problems the stove stops automatically and runs the shutdown process and the display shows text regarding
the motivation of the shutdown (see the various alarms below).
Never pull the plug during shutdown on account of malfunction.
If the stove shuts down, you need to let the Switch-off procedure nish before you can restart the stove.
Do not turn the stove on again before checking the cause of the malfunction and CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION AND INDICATIONS AND REMEDIES:
1) Signalling: AL 01 fume probe faulty or disconnected
Problem: Shutdown due to faulty or disconnected fume probe
Actions: • Check the fume probe connection to the board: check the operation with a cold test (DEALER).
2) Signalling: AL 02 Room sensor fault (this is activated if the probe is faulty or disconnected)
Problem: Shutdown due to detected temperature anomaly
Actions: • Check the connection of the probe to the circuit board (DEALER)
• Check the operation of the sensor (DEALER)
3) Signalling: AL07 Thermal safety (this occurs when the safety thermostat, located on the pellet slide, trips due to over-
temperature in the pellet tank)
Problem: Excessive loading of pellets
Actions: Check operation of motor (DEALER)
4) Signalling: AL 08 depressurisation lacking (this occurs when there is not suf cient draft in the cold air intake pipe)
Problem: The screw feeder is stopped
Actions: • Check that the cold air pipe is not obstructed
• Check the pressure switch
• Check that the silicone tube is not clogged
5) Signalling: AL 09 Failure of fume expulsion motor (this trips if the smoke extraction speed sensor detects a fault)
Problem: Shutdown for smoke extraction speed fault detection
Actions: • Check smoke extractor function (devolution sensor connection) and board (DEALER).
• Check smoke channel for dirt • Verify the electrical system and earthing system.
• Check eletronic circuit board (DEALER).
6) Signalling: AL 10 Failed ignition (intervenes if a ame fails to appear within a maximum of 20 minutes, or if ignition
temperature is not reached).
Problem: Turns off due to incorrect smoke temperature during ignition
Distinguish either of the following cases:
Flame does NOT appear
Actions: Check: - combustion chamber position and cleanliness;
- arrival of combustion air in the combustion chamber;- if the heating element is working (DEALER);
- room temperature (if lower than 3°C use a relighter) and damp. - Try to light with a relighter.
Flames appear, but AF appears on the display after Ar.
Actions: Check: (only by the Dealer)
- • fume probe operation (DEALER);
- start-up temperature setting in the parameters (DEALER).
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Kikka Plus - 2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Kikka Plus - 2016 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info