* The heatable room dimensions are calculated on the basis of pellets with a lhv
of at least 4300 kcal/kg and home insulation in compliance with Italian law 10/91.
It is also important to consider the location of the stove in the room to be heated.
ELECTRICALSPECIFICATIONS
Power supply 230Vac +/- 10% 50 Hz
0/1 switch yes
Average power consumption 150 W
Power consumption during
ignition
400 W
Remote control frequency
(optional)
infrared
Protection on mains power
supply
2A, 250 Vac 5x20
Fuse
Electronic circuit board
protection
2A, 250 Vac 5x20
Fuse
N.B.
1) Bear in mind that external devices may cause interference.
2) Caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
SAFETY DEVICES
THERMOCOUPLE: on the smoke outlet.
It measures the smoke temperature.
It controls the ignition, operating and shutdown
stages according to the parameters set.
AIR FLOW SENSOR: on the intake duct. It trips
when the flow of combustion air is not correct,
therefore causing low pressure problems in the
smoke circuit.
SAFETYTHERMOSTAT:
It trips if the temperature inside the stove is too
high. It stops pellet loading, thus causing the stove
to go out.
THERMOCOUPLE
ROOM
SENSOR
FLOW
SENSOR
SMOKE EXTRACTION
MOTOR
SCREW FEEDER
MOTOR
230 V AC MAINS
50 Hz +/- 10%
VENTILATION
IGNITION
HEATING ELEMENT
SAFETY
THERMOSTAT
2A FUSE
ENGLISH
16
TECHNICALAND HEATINGSPECIFICATIONS
Hopper capacity 15 kg
Efficiency 89,2 %
Available power 3,4 / 8,3 kW
Time between refuellings (min/max) 7,5 / 17 hours
Fuel consumption 0,7 / 2,0 kg/h
Test EN14785 smoke outlet temperature
174,9 °C
Mass flow
5,5 g/s
CO Emissions (13% O2)
71 ppm
Heatable room dimensions (min/max)* 115 / 230
m
3
Weight including packaging 157 kg
Smoke duct diameter (Amale) 80 mm
Air intake duct diameter (B male) 40 mm
SMOKE SPEED
P/TEMP.
ADJUSTMENT
VENTILATION
ADJUSTMENT
The Dealer can install an optional on the AUX outlet
(clean contact, with no potential) for controlling the
process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove.
Can be connected via special optional trestle (code 621240).
600 mm
215 mm
77 mm
* 308/325 mm
* with screwed in feet
* 367/380 mm
106 mm