ASSEMBLY AND INSTALLATION
The stove is delivered on a pallet inside a cardboard box. First of all, remove the stove from its packaging, check that the model
is the one ordered, and make sure it has not been damaged during transportation. Any complaints must be made to the carrier (in
writing on the accompanying consignment note) upon receipt. Refer to the local regulations in the country of use for assemby and
anything else not expressly shown. In Italy, refer to standard UNI 10683/2005, along with any regional or local health authority
regulations. If the stove is to be installed in a condominium, consult the administration before installing.
COMPATIBILITY WITH OTHER DEVICES
According to the regulation UNI 10683/05, the stove must NOT be installed in the same room as extractors, type B gas equipment
or any device creating vacuum conditions.
Warning: extraction fans operating in the same room can cause problems.
SMOKE DUCT
The smoke duct connects the smoke outlet to the ue inlet. The smoke duct must be made with steel or ceramic rigid pipes.
Flexible metal pipes or bre-cement pipes are not allowed. Horizontal and counterslope sections should be avoided. Any
cross-secion change should be made in correspondence of the stove outlet and not at the ue inlet.
sealed with high temperature resistant mastic.
FLUE
the same ue worked correctly does not necessarily mean the new one will work well.
- W
size of the ue must comply with the specications indicated in the technical data (see table at page 14). We recommend using
insulated circular section ues made of refractory material or stainless steel with smooth internal walls.
The ue cross-section should be constant for its whole length (we recommend a minimum height of 3.5 - 4 m).
- We recommend tting a chamber at the base of the ue to collect solid material and any condensate. Dilapidated ues and ues
made of unsuitable materials (asbestos, galvanized steel, corrugated iron, etc.) with rough or porous internal surfaces are illegal
and detrimental to stove operation.
- The ue should be used for one single stove only (it cannot receive the outlet of other reboxes)
- For a good draught, the ue should be free from obstructions, such as bottlenecks, horizontal sections and sharp edges; any
nonvertical
sections should slope by not more than 45° from the vertical (g. 3).
- If -
tion
and avert the risk of unburnt deposits on the internal ue walls catching re.
- In normal working conditions, the ue must be cleaned at least once a year.
- For optimal operation, the ue draught must create a pressure drop between 0.12 and 0.2 mbars. Lower values may lead to
unpleasant smoke emissions when loading the stove and produce excessive soot deposits; higher values would lead to excessively
fast combustion and a decrease in thermal efciency. To fall within the correct values, refer to the UNI Standard 10683/2005 table.
- If
cm higher than the others.
Please refer to the chapter of the UNI 10683/2005 regulation regarding positioning of chimney pots.
- We recommend installing a re damper on the smoke duct.
ENGLISH
ENGLISH
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Evolution Line - Chic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Evolution Line - Chic in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info