POSSIBLE TROUBLESHOOTING
In the event of problems the stove stops automatically and runs the shutdown process and the display shows text
regarding the motivation of the shutdown (see the various alarms below).
Never pull the plug during shutdown on account of malfunction.
Should it block, to restart the stove you will need to allow the turn-off procedure to take place (600 seconds with
audible signal), and then press the button .
Do not turn the stove on again before checking the cause of the malfunction and CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION INSTRUCTIONS AND SOLUTIONS:
1) Segnalazione: Signalling: Veric./extract.: (this trips if the smoke extraction speed sensor detects a fault)
Problem: Shutdown for smoke extraction speed fault detection
Actions: • Check smoke extractor function (revolution sensor connection) and board (DEALER).
• Check smoke channel for dirt
• Verify the electrical system and earthing system.
• Check eletronic circuit board (DEALER).
2) Signalling: Stop/Flame: (this trips if the thermocouple detects a smoke temperature lower than the value set, which it
interprets as the absence of ames)
Problem: Turns off due to drop in smoke temperature
Flame may fail for any of the following reasons:
- lack of pellets
- too many pellets have suffocated the ame, check pellet quality (DEALER)
- the maximum thermostat has intervened (rare, this only intervenes in the event of excessive smoke
temperature) (DEALER)
- The safety pressure switch comes on because of clogging/blockage of the smoke discharge pipe or
the ue (have it checked by a qualied technician - chimney sweep)
- Activation of the safety thermostat of the tank. Check that around the stove there aren’t any objects
blocking the ventilation or whether the fans are broken or off, in which case call the DEALER.
3) Signalling: Block_FI/NO Start: (intervenes if a ame fails to appear within a maximum of 15 minutes, or if ignition
temperature is not reached).
• Check correct functioning of the pressure switch (CAT)
Problem: Turns off due to incorrect smoke temperature during ignition
Distinguish either of the following cases:
Flame does NOT appear
Actions: • Check: - combustion chamber position and cleanliness;
• Check that there are pellets in the tank and the re box
• arrival of combustion air in the combustion chamber;
• if the heating element is working (DEALER);
• room temperature (if lower than 3°C use a relighter) and dampness.
Try to light with a relighter (see page 41).
Flames appear, but AF appears on the display after Ar
Actions: • Check: (only by the Dealer)
• if the thermocouple is working (DEALER);
• start-up temperature setting in the parameters (DEALER).
4) Signalling: Black/Out: (not a defect of the stove).
in PELLET mode, the power outage block is automatically reset. In “LIGHT WOOD” mode, the lack of
power is simply indicated as a possible cause of the WOOD not lighting, without triggering the block.
5) Signalling: Fault/RC: (intervenes if the thermo coupling has failed or is disconnected).
Problem: Turns off due to thermo coupling failed or disconnected
Actions: • Check connection of thermo coupling to board: check function in cold test (DEALER).
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Demy at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Demy in the language / languages: English as an attachment in your email.

The manual is 5.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Demy

Edilkamin Demy Usermanual and installation guide - German - 28 pages

Edilkamin Demy Usermanual and installation guide - Dutch - 28 pages

Edilkamin Demy Usermanual and installation guide - French, Italian - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info