810907
13
Zoom out
Zoom in
Previous page
1/28
Next page
13
ENGLISH
ritorno 3/4”
carico/scarico
mandata 3/4”
valvola sicurezza
3 bar
100
Ø 8 cm uscita fumi
Ø 4 cm aria
combustione
122
43
122
100
43
11,5 38,5
34,5
41
10
19
Ø 8 cm uscita fumi
4,5 14,5
11
19
15,5
18
21,5
TC
ritorno 3/4”
carico/scarico
mandata 3/4”
valvola sicurezza
3 bar
100
Ø 8 cm uscita fumi
Ø 4 cm aria
combustione
122
43
122
100
43
11,5 38,5
34,5
41
10
19
Ø 8 cm uscita fumi
4,5 14,5
11
19
15,5
18
21,5
TC
ritorno 3/4”
carico/scarico
mandata 3/4”
valvola sicurezza
3 bar
100
Ø 8 cm uscita fumi
Ø 4 cm aria
combustione
122
43
122
100
43
11,5 38,5
34,5
41
10
19
Ø 8 cm uscita fumi
4,5 14,5
11
19
15,5
18
21,5
TC
• HYDRAULIC CONNECTIONS:
HEATING SYSTEM WITH THE THERMO STOVE AS THE ONLY HEAT SOURCE
HEATING SYSTEM WITH THE THERMO STOVE AS THE ONLY SOURCE OF HEAT, WITH SANITARY HOT
WATER BEING PRODUCED BY A BOILER
HEATING SYSTEM WITH THE THERMO STOVE COMBINED WITH A BOILER
ACCESSORIES:
In the diagram shown above, the use of the accessories available on the EDILKAMIN S.p.A. pricelist is assumed.
Individual spare parts are also available (exchanger, valves, etc). For information, please contact your local dealer.
LEGEND
ACS: Household hot water
AL: Water supply input
B: Boiler
C: Fill/Top up
EV2: 2-way electro-valve
EV3: 3-way electro-valve
NA: Normally Open
NC: Normally Closed
GR: Pressure reducer
MI: System in
P: Pump (circulation)
RA: Radiator
RI: System return
S: Drain
TC: Boiler-stove
V: Spherical valve
Vec: Closed surge tank
VSP: Safety valve
LEGEND
ACS: Household hot water
AF: Cold water
AL: Water supply input
C: Fill/Top up
GR: Pressure reducer
MI: System in
P: Pump (circulation)
RA: Radiators
RI: System return
S: Drain
SB: Water boiler
ST: Temperature probe
TC: Boiler-stove
V: Spherical valve
VA: Automatic air vent
Vec: Closed surge tank
VSP: Safety valve
VST: Thermal discharge valve
LEGEND
AF: Cold Water
AL: Water supply
C: Filling/Topping up
GR: Filling unit
MI: Outlet to system
P: Pump (circulator)
RA: Radiators
RI: Inlet from system
S: Drain
ST: Temperature Detector
TC: Boiler-stove
V: Ball valve
VA: Automatic bleed valve
Vec: Closed Expansion Tank
VSP: Safety Pressure Valve
VST: High Temperature
Drainage Valve
manifold
manifold
manifold
internal boiler-stove components
internal boiler-stove components
internal boiler-stove components
This layout is purely indicative. Have a plumber design and install the system.
INSTALLATION
INSTALLER
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Daisy at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Daisy in the language / languages: English as an attachment in your email.

The manual is 5.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Daisy

Edilkamin Daisy Usermanual and installation guide - German - 28 pages

Edilkamin Daisy Usermanual and installation guide - Dutch - 28 pages

Edilkamin Daisy Usermanual and installation guide - French, Italian - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info