810724
16
Zoom out
Zoom in
Previous page
1/72
Next page
ENGLISH
16
Important warnings
As well as that indicated in the present
document, bear in mind the UNI rules:
- n. 10683 - wood heat generators:
installation requirements
- n. 9615/90 - calculation of the chimney
internal dimensions.
In particular:
- before starting any mounting operation,
it is important to verify the compatibility of the
plant as established by the UNI 10683 rule
in paragraphs 4.1/ 4.1.1 / 4.1.2.
- once mounted, once mounted, the
installer must “start up” the plant and issue
the documentation requested in the UNI
10683 rule, respectively in paragraphs
4.6 and 5.
Before installing the cover, verify
the correct functioning of the
connections, the controls and all
moving parts.
The veri cation must be carried
out with the chimney having been
on for a few hours, before covering the
hearth, in order to eventually intervene.
Therefore, the finishing operations such
as for example:
- manufacture of the false hood
- mounting of covering
- carrying out stripping, painting, etc.
must be carried out once tested with
positive result.
Therefore, Edilkamin does not answer for
burdens deriving from both demolition
and reconstruction interventions, even if
subsequent to replacing hearth pieces
which resulted faulty.
Calibration and start up to be carried
out by the dealer.
Vorwort
• The CRISTAL hearths must be installed keeping
to the following instructions, as the safety and plant
efficiency depend on the correct installation.
• Carefully read the present instructions before
mounting.
• EDILKAMIN declines any responsibility for
eventual damages deriving from the non
compliance with the present instructions and, in
case, any warranty right will be void.
• The CRISTAL hearth is supplied already
assembled on non returnable pallet.
The inside covering of the hearth is supplied
already installed
• A model identification label is applied under
the hearth hatch; the label can be seen until the
hearth is covered.
The model identification number is indicated in
the documentation supplied with the product.
Building protection
All the building surfaces near the hearth must be
protected against over-heating. The insulating
measures to be adopted depend on the type of
surfaces present and how they are made.
Hot air outlets / Grillsr
The hot air outlets must be placed at a minimum
distance of 50 cm from the ceiling and 30 cm
from the furniture.
Position the grills or the air outlets at the highest
point of the covering, in order to avoid heat
accumulating inside the same covering. Position
the grills or the air outlets so that they can be
easily accessed for cleaning.
Heating insulation
The insulating layers must not have joints and
have to be overlapped. The thickness of the
insulating material must be of at least 3 cm.
Ornamental beams
The realisation of eventual wood ornamental
beams in front of the hearth covering is allowed
only if they are outside the radiation field, at a
distance of at least 1 cm from the same covering.
The air space which isolates the ornamental
elements and the covering must be such not to
accumulate heat.
The wood ornamental beams cannot be
integrating parts of the building.
Floor opposite the hearth
Floors made with fuelling materials must be
protected by a sufficiently thick, non fuelling
cover. The floor protection must be equal to:
frontally: - the corresponding height of the fire
surface from the floor plus 30 cm and, in any
case, min. 50 cm
laterally: - the corresponding height of the fire
surface from the floor plus 20 cm and, in any
case, min. 30 cm.
In the radiation eld of the hearth
The structural elements built with fuelling material
or which present fuelling components and the
furniture must be positioned at a minimum
distance of 80 cm from the hearths mouth, in all
three directions: front, upper and side.
Should such elements or furniture be screened
by a ventilated anti-radiation protection, it will be
sufficient to respect a distance of 40 cm.
Outside the radiation eld
The structural elements built with fuelling
materials or which present fuelling components
and furniture, must be positioned at a minimum
distance of 5 cm from the hearths covering.
In such air space, the air present in the room
must be able to circulate freely. No heat
accumulation must be created.
Electric lines
There must be no electric lines in the walls and
the ceilings, including the hearth embedding
area.
Movement inlets
Two rings (A) have been prearranged to facilitate
the conveying of the monobloc on the sides of
the hearth.Insert the two steel pipes provided, in
the rings.
The two tubulars will serve as inlets for the
hand conveying of the monobloc, after having
eventually lightened it by removing the entire
Ecokeram earth (about 70 kg).
INSTALLATION INSTRUCTIONS
AA
Note: The product is supplied with
two anti-corrosion discs (one on the
outside and one on the inside of the
combustion chamber). They must
be removed during unpacking and
disposed of as normal waste.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Cristal 90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Cristal 90 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info