810904
90
Zoom out
Zoom in
Previous page
1/92
Next page
90
A07
Switch-off due to high smoke temperature.
Check the type of pellets (if in doubt,
contact technician)
Contact the technician
A08
Switch-off due to excessive temperature of the
product
Check the type of pellets (if in doubt,
contact technician)
Contact the technician
A09
Switch-off due to breakage or blockage of the
pellet loading auger motor
Check that the pellet hopper is not
obstructed
Contattare il tecnico
A10
Switch-off due to electronic motherboard
overheating.
Contact the technician
A11
Switch-off due to tripping of the safety
pressure switch.
Check that the stove and the exhaust
are clean
Contact the technician
A12
Room temperature probe faulty.
Contact the technician
A13
Switch-off due to breakage of product water
temperature probe.
Contact the technician
A14
Switch-off due to breakage of water
temperature probe in cylinder
Contact the technician
A15
Switch-off due to exceeding the maximum
water temperature of product
Contact the technician
A16
Switch-off due to breakage of pressure switch
that reads product water pressure
Contact the technician
A17
Switch-off due to breakage of external probe
Contact the technician
A18
Switch-off due to breakage of water
temperature probe in inertial storage tank.
Contact the technician
A19
Switch-off due to required crucible cleaning or
problem on cleaning system
For products with AshKontrol”: clean
the “combs” (see “Daily Maintenance”
chapter)
Contact the technician
A20
Triggers when the electronic board detects
movement of the pellet loading auger motor
when it does not require feeding
Contact the technician
A21
Black-out
Switch-off due to power failure; not normally a
product defect
Check electrical connections and
voltage dips
Contattare il tecnico
A23
Switch-off due to panel overheating
Contact the technician
A24
2AT fuse faulty on electronic motherboard
Contact the technician
A25
Inconsistent state
Contact the technician
If the water in the product reaches a temperature of 85°C, the product switches off without going into alarm.
The message STBY appears on the display next to the room temperature.
The product works, but maintenance must be carried out by the Edilkamin qualified technician.
90


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Cherie H Evo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Cherie H Evo in the language / languages: English as an attachment in your email.

The manual is 10.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Cherie H Evo

Edilkamin Cherie H Evo Usermanual and installation guide - German - 94 pages

Edilkamin Cherie H Evo Usermanual and installation guide - Dutch - 93 pages

Edilkamin Cherie H Evo Usermanual and installation guide - French - 95 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info