810754
8
Zoom out
Zoom in
Previous page
1/84
Next page
8
ENGLISH
EDILKAMIN S.p.A. The manufacturer reserves the right to modify the product without
notification in the interests of improvement.
TECHNICAL DATA
USER/INSTALLER
ELECTRICAL SPECIFICATIONS
Power supply 230 Vac +/- 10% 50 Hz
Nominal absorbed power 177 W
Reduced absorbed power 68 W
Absorbed power in stand-by mode 3 W
Power absorption during ignition 365 W
Remote control frequency (provided) 2.4 GHz
Protection rating Fuse 4 AT 250 V AC 5x20
TECHNICAL CHARACTERISTICS pursuant to EN 14785 The data shown is purely indicative and was
measured during the certification phase at a notified body under standard conditions.
The results were obtained with the glass cleaning system off. Use the gasket provided (to
be done by the installer).
CHERIE 9 EVO ATC/ CHERIE 9 EVO AT
Nominal power Reduced power
Available power 9 3,7 kW
Yield 89,2 93,1 %
CO emissions at 13% O20,004 0,006 %
Smoke temperature at smoke outlet 171 95,2 °C
Fuel consumption * 2 0,8 kg/h
Tank capacity 16 kg
Draw 11,1 10,1 Pa
Autonomy *** 9/23 hours
Heatable volume ** 235 m3
Smoke duct diameter 80 mm
Weight including packaging
(steel/ceramic/soap stone) 216/218/250 -- kg
Energy efficiency class in accordance with EU
regulation 2015-1186 (Classes A++/G) A+ --
* A calorific value of 4.8 kW/kg was used to calculate consumption.
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
*** The autonomy may vary in relation to the usage/installation/fuel characteristics and is not contractually binding nor can it
constitute grounds for dispute.
*** Accessories for ducting hot air are available.
The product can work safely even with greater draught.
Excessive draught could cause the product to switch off and/or lower its performance.
NOTE: the smoke outlet diameter does not match the chimney system diameter, which must be
sized accordingly.
TECHNICAL DATA FOR SIZING THE FLUE
which must in any case satisfy the requirements of this sheet and the installation instructions
Nominal power Reduced power
Smoke temperature at smoke outlet 205 114 °C
Minimum draught 0,001 Pa
Smoke flow rate 7,1 3,7 g/s
Firebox classification according to pr EN16510
CC 50
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Cherie 11 Evo AT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Cherie 11 Evo AT in the language / languages: English as an attachment in your email.

The manual is 5.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Cherie 11 Evo AT

Edilkamin Cherie 11 Evo AT Usermanual and installation guide - German - 84 pages

Edilkamin Cherie 11 Evo AT Usermanual and installation guide - Dutch - 84 pages

Edilkamin Cherie 11 Evo AT Usermanual and installation guide - French - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info