810825
12
Zoom out
Zoom in
Previous page
1/60
Next page
12
ENGLISH
INSTALLATION
INSTALLER
COMBUSTION AIR INTAKE
The inflow of necessary air for combustion, of air for
glass cleaning and heating air renewal must come
from the outside
Sealed stoves can also be installed in
passive houses. In this case, the air inlet
must be a direct air inlet
The stove takes the air from the outside
via the air inlet hole.
Install an air intake with an effective
surface area (net of the mesh or other
protective equipment) at least equal to the
cross section of the air inlet hole.
Connect the air intake to the appliance’s air intake with
a pipe that may also be flexible. Increase the diameter
of the pipe if the pipe is not smooth or if it is necessary
due to load losses: assess the load losses.
We recommend that it does not exceed 1 metre in
length or include any bends.
If you are not interested in the sealing feature of the
appliance, you can create an indirect air intake, even if
this is not recommended
Install an air outlet at floor level with an effective sur-
face area (net of the screen or other protections) of at
least 80 cm2 (diameter 10 cm).
To prevent draughts, we recommend installing the
intake behind the product or behind a radiator.
Installing it in front of the appliance will create
unpleasant draughts.
The air may be drawn from an adjacent room only if:
the flow is taken from permanent, unobstructed
openings communicating with the outdoors
the air pressure in the adjacent room is never
reduced to a level below outdoor pressure
the adjacent room is not a garage, subject to fire
hazard, a bathroom or a bedroom
the adjacent room is not a shared room in the
condominium
In Italy, UNI 10683 provides that ventilation is sufficient
even if a pressure difference between the outdoors
and indoors of no more than 4 PA is guaranteed (UNI
EN 13384-1). The installer who issues the declaration
of conformity is responsible for ensuring these
conditions.
USE OF CONCENTRIC PIPES
USE OF CONCENTRIC PIPES
Without prejudice to the general instructions, you can
use concentric pipes (which provide for the passage of
smoke inside and the passage of the combustion air
into the external circular ring).
This type of installation only needs one hole in the wall,
instead of having one hole for the air intake and one for
the smoke discharge.
stufa
scarico fumi sopra
presa aria sopra
con uso coassiale
Examples of possible installations. For the smoke
discharge conditions (on roof, etc.) check local
regulations for sealed pellet stoves.
Upper coaxial fumes discharge and air
intake
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Celia Air Tight at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Celia Air Tight in the language / languages: English as an attachment in your email.

The manual is 1.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Celia Air Tight

Edilkamin Celia Air Tight User Manual - German - 56 pages

Edilkamin Celia Air Tight User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info