OPERATIONAL LOGIC
the product operates with the POSSIBLE MODES (described below):
OFF MODE
ON MODE
STAND BY MODE
ALARM MODE
OFF MODE
The product is “disabled” and does not produce heat. The product may turn on only for the anti-freeze function
(described on this page). You can set the product to the OFF mode by pressing the ON/OFF button on the display.
Also an external contact (crono, phone dialler) may switch the boiler stove to the OFF mode.
Pressing the +/- keys has no effect. Pressing the M key displays the Menus.
The display shows the current time, room temperature and the status in relation to which the product is OFF.
The product can be in the OFF mode in these cases:
due to manual operation of the user (with probe)
due to manual operation of the user (with thermostat)
due to crono
due to Black Out
USER
ANTI-FREEZE (selectable from the Menu
only by the Technical Assistance Centre
during commissioning)
Can only be activated from OFF and STAND-BY
modes.
The function preserves only the heating circuit, not the
domestic hot water circuit.
The anti-freeze has two levels:
level 1: pump on
level 2: pump and boiler stove on; it is activated
by the anti-freeze mode “level 1” if the probe
temperature reads a temperature which is below
the Anti-freeze Setpoint.
The activation of the anti-freeze (both level 1 and level
2) is indicated by the symbol “frost” on the display.
SPECIFICA TECNICA
Nome:
Rev:
Data:
Pagina
IDRO 2017
0.0
30/09/2016
15 / 52
Il contenuto di questo documento è proprietà di EdilKamin S.p.A. e non p essere riprodotto o divulgato a terzi senza autorizzazione.
3.4 Antigelo
La funzione Antigelo si attiva esclusivamente dagli stati OFF e STAND-BY quando la
funzione antigelo è attiva (defaultNon attiva”) e in funzione della temperatura letta dalla
sonda di caldaia e della temperatura letta dalla sonda esterna (se presente e collegata).
La temperatura Sonda Esterna viene filtrata con un tempo congruo.
L’antigelo funziona anche se è presente la sonda bollitore o la sonda accumulo.
La funzione preserva esclusivamente il circuito riscaldamento, non il circuito sanitario.
La condizione di attivazione dellantigelo Livello 1 (pompe on) è:
TempCald < SetAntigelo +C OR
TempEsterna < SetAntigelo – 3°C
per almeno 200 secondi
Le condizioni di attivazione dellantigelo Livello 2 (pompe e fiamma on) sono:
Dallo stato antigelo Livello 1
TempCald < SetAntigelo
per almeno 300 secondi
Azioni
ANTIGELO LIVELLO 1:
Viene attivata la pompa PWM al massimo e la pompa esterna con un ciclo di
comando pari a 10’ ON e 120’ OFF
Se la valvola 3 vie è in sanitario si porta la valvola 3 vie in riscaldamento
Se la (TempCald > SetAntigelo +C) AND (TempEsterna > SetAntigelo -C) il
ciclo di comando delle pompe termina. La 3 vie torna al normale funzionamento,
le pompe vengono spente e si esce dallo stato.
Se TempCald < SetAntigelo si entra nellantigelo di Livello 2
ANTIGELO LIVELLO 2 (procedura di accensione standard):
Se la valvola 3 vie è in sanitario si porta la valvola 3 vie in riscaldamento.
La stufa viene accesa secondo la procedura di accensione
La stufa rimane in Stabilizzazione di Fiamma e esce quando TempCald >
Ton_Pompa, a questo punto va in Spegnimento e le pompe si spengono quando
TempCald < Ton_Pompa.
L’attivazione della funzione antigelo (sia livello 1 che livello 2) è segnalata da un simbolo.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Blade H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Blade H in the language / languages: English as an attachment in your email.

The manual is 9.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Blade H

Edilkamin Blade H Usermanual and installation guide - German - 52 pages

Edilkamin Blade H Usermanual and installation guide - French, Italian - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info