To manage the various types of systems, connect the probes to the terminal board, as needed.
FOR THE INSTALLER: HYDRAULIC INSTALLATION
INSTALLER
There are 4 pre-set configurations as shown below.
TERMINAL BOARD MAIN OUTLINE
15-16 CYLINDER PROBE (Optional NTC 10K ) or THERMOSTAT (Optional)
13-14 DOMOTIC CONTACT (Input)
11-12 ROOM PROBE (Supplied) or ROOM THERMOSTAT (Optional)
9-10 BUFFER PROBE (Optional NTC 10K) - BUFFER THERMOSTAT (Optional)
7-8 BUFFER-CYLINDER DOUBLE PROBE (Optional NTC 10K probe)
4-5-6 AUX CONTACT - Output, aux boiler room thermostat or 3-way valve
(COM = Common - NC = Normally Closed - NO = Normally Open).
1-2-3 SECONDARY PUMP POWER SUPPLY (Earth / Neutral / Phase)
HOME AUTOMATION CONTACT 13-14
For all types of systems:
HEATING - KETTLE - PUFFER - PUFF / TUB
it is possible to connect a remote control with clean contact (closed on request, open not on
request).
This contact has the same function as the on / off button on the display.
Following the closure of the contact, however, the thermo stove will follow its objective defi-
ned by the selected system and the functions associated with it, as happens when the power
button on the display is pressed.
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Blade H 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Blade H 15 in the language / languages: English as an attachment in your email.

The manual is 4.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Blade H 15

Edilkamin Blade H 15 Usermanual and installation guide - German - 88 pages

Edilkamin Blade H 15 Usermanual and installation guide - French - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info