810901
33
Zoom out
Zoom in
Previous page
1/56
Next page
EN Installation, use and maintenance page 2
PELLET BOILER STOVE BLADE H 18-22
2
ENGLISH
The undersigned EDILKAMIN S.p.A., with registered office in
Via Vincenzo Monti 47 - 20123 Milan (Italy) - Tax ID Code and
VAT number 00192220192
Hereby declares, under its sole responsibility, that:
the pellet boiler stoves mentioned below are conforming with
EU Regulation 305/2011 and harmonised EU standard EN
14785:2006
PELLET BOILER STOVES, bearing the
EDILKAMIN trademark, models
BLADE H 18 e BLADE H 22
SERIAL NO.: Rating plate reference
BLADE H 18 : Performance declaration (DoP - EK no. 154)
BLADE H 22 : Performance declaration (DoP - EK no. 155)
Moreover, the company hereby declares that:
the wooden pellet boiler stoves BLADE H 18 e BLADE H
22 comply with the requirements in the following European
Directives:
2014/35/EC - Low Voltage Directive
2014/30/EC - Electromagnetic Compatibility Directive
CONTENTS
USER/INSTALLER
The original language of this manual is Italian
Introduction and readers of this manual 3
Introduction and readers of this manual 3
Safety information 4
Safety information 4
Dimensions 5
Dimensions 5
Technical data 7
Technical data 7
Unpacking 10
Unpacking 10
Water circuit installation 11
Water circuit installation 11
Terminal board 16
Terminal board 16
Installation 17
Installation 17
Installation of steel lining 21
Installation of steel lining 21
Installation of ceramic lining 28
Installation of ceramic lining 28
Introduction about use 33
Introduction about use 33
Display 34
Display 34
Operational logic 36
Operational logic 36
Commands and Menu 39
Commands and Menu 39
Stand By 40
Stand By 40
Crono 41
Crono 41
Temperatures 44
Temperatures 44
Ventilation, Pellet Load, Language 45
Ventilation, Pellet Load, Language 45
Beep, Date/Time, Pressure, Technical Menu 46
Beep, Date/Time, Pressure, Technical Menu 46
Maintenance 47
Maintenance 47
Troubleshooting 50
Troubleshooting 50
3
ENGLISH
Dear Sir/Madam
We thank you for and congratulate you on choosing our
product. Before using it, we ask you to read this manual
carefully, in order for you to be able to make the most of all
its functions in total safety.
This manual is an integral part of the product. We ask you
to keep it for the entire lifetime of the product. If you lose it,
you can request a copy from your dealer or download it from
www.edilkamin.com
Readers of this manual
This manual is addressed to:
those who will use the product at home (“USER”);
the technician who will install the product (“INSTALLER”)
The target person of each page is indicated in a band at the
bottom of the page (USER or INSTALLER).
General information
After unpacking the product, check the condition and
completeness of the contents.
In the event of error, immediately contact the retailer where
the purchase was made, providing them with a copy of the
warranty booklet and the sales receipt.
The appliance must be installed and operated in compliance
with local and national law and European regulations. For the
installation, and for anything not specifically indicated in the
manual, observe local regulations.
The diagrams provided in this manual are for illustration
purposes only: they do not always strictly refer to your
specific model, and are not binding in any way.
MEANING OF SYMBOLS
In some parts of the manual the following symbols are
used:
INFORMATION:
failure to comply with these requirements
will compromise product use.
PLEASE NOTE:
carefully read and understand the
message in question, since failure to
follow the instructions in it could cause
serious damage to the product and put
the safety of those using it at risk.
OPERATING SEQUENCE:
follow the instructions for the operations
described.
Identification of the product and warranty.
The product is uniquely identified by a number, the
“counterfoil”, which is indicated on the warranty certificate.
Please keep:
the warranty certificate accompanying the product
the purchase receipt given to you by the retailer
the declaration of conformity given to you by the installer.
The warranty conditions are given in the warranty certificate
accompanying the product.
First ignition (commissioning), in Italy, by an
authorised technician is required by UNI 10683, and is
recommended in all countries to ensure best results from
the product.
This consists of:
checking the installation documents (declaration of
conformity) and the quality of the installation itself
calibrating the product to suit its actual application
providing explanations to the end user and issuing
the complementary documentation (first ignition -
commissioning certificate)
Having the appliance commissioned properly ensures that it
will operate to best effect and in complete safety.
Commissioning is required for activation of the Edilkamin
manufacturer warranty. The warranty is only valid in the
country where the product was bought.
If the appliance is not commissioned by an authorised
technician, Edilkamin will not provide warranty service. See
the warranty booklet for details. The above terms do not
affect the dealer's legal responsibility for the legal warranty.
The warranty, however, covers only demonstrable
manufacturing defects and not, for instance, problems
resulting from improper installation or calibration.
USER/INSTALLER
4
ENGLISH
SAFETY INFORMATION
The product is not designed for use by people,
including children, with limited physical, sensory
and mental abilities.
The appliance is not designed for cooking
purposes.
The appliance is designed to burn wood pellets
from category A1 in the UNI EN ISO 17225-2
standard, in the amounts and manner described
in this manual.
The appliance is designed for indoor use and in
areas with normal humidity conditions.
Keep the product in a dry place out of the weather.
For the legal and company warranties, refer to the
warranty certificate inside the product: specifically,
neither Edilkamin nor the retailer are liable for
damage resulting from incorrect installation or
maintenance.
Safety risks may be caused by:
installation in non-suitable settings, in particular
those that are subject to fire risks. DO NOT
INSTALL THE PRODUCT IN AREAS SUBJECT TO
THE RISK OF FIRE.
contact with fire and hot parts (e.g. glass panel
and pipes). DO NOT TOUCH HOT PARTS and,
when the stove is switched off and still hot, always
wear the glove.
contact with live electrical equipment (internal).
DO NOT ACCESS THE INTERNAL ELECTRICAL
EQUIPMENT WHILE THE APPLIANCE IS
POWERED ON. Electrocution hazard.
use of improper ignition aids (e.g. alcohol). DO
NOT IGNITE OR BOOST THE FLAME WITH FLUID
SPRAYS OR A FLAME TORCH. Serious risk of
burns, damage and injury.
use of fuel other than wood pellets. DO NOT
BURN WASTE MATTER, PLASTIC OR OTHER
MATERIALS THAN WOOD PELLETS IN THE
COMBUSTION CHAMBER. The product may
become soiled, the flue may catch fire, and
environmental damage may ensue.
cleaning the combustion chamber when hot. DO
NOT CLEAN THE HEARTH WITH A VACUUM
CLEANER WHILE IT IS HOT. You could damage
the vacuum-cleaner and risk the emission of
smoke in the room.
cleaning the smoke duct with cleaning products. DO
NOT CLEAN THE PRODUCT WITH FLAMMABLE
PRODUCTS. Risk of fire or blowback.
cleaning the glass pane while hot or with unsuitable
cleaning products. DO NOT CLEAN HOT GLASS
WITH WATER. ONLY USE RECOMMENDED
GLASS CLEANING PRODUCTS. Risk of cracking
and permanent, irreparable damage to the glass.
the storage of flammable materials at a distance
which is less than the safe distances listed in
this manual. DO NOT PLACE LAUNDRY ON
THE APPLIANCE. DO NOT PLACE DRYING
RACKS WITHIN THE SAFETY CLEARANCE. Keep
flammable fluids away from the appliance. Fire
hazard.
blocking the aeration vents and air intakes in the
room. DO NOT BLOCK THE AERATION VENTS
OR FLUE. Risk of smoke returning into the room
with consequent damage and injury.
use of the product as a support or ladder. DO NOT
CLIMB ONTO THE PRODUCT OR USE IT AS A
SUPPORT. Risk of damage and injury.
use of the stove with the combustion chamber
open. DO NOT USE THE PRODUCT WITH ITS
DOOR OPEN.
incandescent material projected from the open
door. DO NOT throw incandescent material
outside the appliance. Fire hazard.
use of water in case of fire. CALL THE AUTHORITIES
if a fire breaks out.
never operate the product without water in the
circuit.
running it dry can damage it.
If you have doubts, please do not take any action, but
contact the retailer or the installer.
For reasons of safety, read the user instructions
included in this manual.
USER/INSTALLER
5
ENGLISH
DIMENSIONS
USER/INSTALLER
105
39
10
Ø 8 cm
smoke outlet
120.5
120.5
39
Ø 8 cm
smoke outlet
7
71
7.5
Ø 5 cm
combustion air
Ø 8 cm
smoke outlet with
optional element
10 25.5
71
61
18
*
* space for housing the R, R2 or RW (Blade
H22) hydraulic kit. Information on the kit manual.
The boiler stove is supplied standard with the top smoke outlet female.
An optional kit is available for the rear or side smoke outlet.
BLADE H 18–22 STEEL (cm)
6
ENGLISH
DIMENSIONS
BLADE H 18–22 CERAMIC (cm)
USER/INSTALLER
105
39
10
Ø 8 cm female
standard smoke outlet
121.5
120.5
39
71
7.5
Ø 5 cm
combustion air
Ø 8 cm male
smoke outlet with
optional element
10 25.5
71
61
The boiler stove is supplied standard with the top smoke outlet female.
An optional kit is available for the rear smoke outlet.
18
*
* space for housing the R, R2 or RW (Blade
H22) hydraulic kit. Information on the kit manual.
7
ENGLISH
The above data is for guidance only and was measured during certification by a notified body.
EDILKAMIN S.p.A. reserves the right to modify the product without notice for the purpose of
improving it.
TECHNICAL SPECIFICATIONS as per EN 14785
BLADE H 22 BLADE H 18 BLADE H 18–22
Nominal power Reduced power
Available power 22.5 18.7 4.9 kW
Power available to water 20 16.3 3.8
Efficiency 92.7 93.3 95.1 %
CO emissions at 13% O20.012 0.013 0.007 %
Fumes temperature 114 101 54 °C
Fuel consumption 5.1 4.2 1.1 kg/h
Tank capacity 30 kg
Recommended draught 11 11 11 Pa
Autonomy 6 7 26 hours
Water content 20 l
Maximum operating pressure 2 bar
Maximum operating temperature 90 °C
Heatable volume * 585 485 m3
Fume duct diameter (female) 80 mm
Air intake duct diameter (male) 50 mm
Weight with packaging (ceramic/steel) 280 kg
Energy efficiency class according to UE
2015-1186 regulation (Class A++/G) A+
TECHNICAL DATA FOR SIZING THE FLUE
which must nonetheless satisfy the requirements of this sheet and the product’s installation instructions
Nominal power
BLADE H 22 BLADE H 18
Fume temperature at smoke outlet 137 122 °C
Minimum draught 0.01 Pa
Fume flow rate 15.1 13.4 rps
*A calorific value of 4.8 kW/Kg has been used to calculate consumption.
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
ELECTRICAL SPECIFICATIONS
Power supply 230 V AC +/- 10% 50 Hz
Mean absorbed power 50–80 W
Power absorption during ignition 300 W
Protection rating Fuse 4 AT 250 V AC 5x20
TECHNICAL DATA
USER/INSTALLER
8
ENGLISH
ECODESIGN TECHNICAL DATA
USER/INSTALLER
Manufacturer Edilkamin S.p.A.
Trademak Edilkamin
Model Identifier Blade H 18 Kira H 18 Vyda H 18
Description Mechanically space heater fired by wood pellets
Indirect heating functionality yes
Direct heat output (space heat output) 2,4 kW
Indirect heat output (space heat output) 16,3 kW
CPR harmonised standard EN 14785
Notified Body Kiwa Cermet Italia (San Vendemiamo, Treviso, Italy) NB 0476
Fuel Preferred fuel
(unique)
PM OGC CO NOx PM OGC CO NOx
Compressed wood with moisture content < 12 % yes 14 4 163 121 21 3 93 114
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022 From 01/01/2022
ɻ
s
[%] 89,4 ɻ
s
[%] 82,4
EEI [%] 131 EEI [%] 124
Energy Efficiency Class A++ A+
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
BLF =1,45
F5 not of relevance
Heat output Useful efficiency (NCV as received)
Item Symbol Value Unit Item Symbol Value Unit
Nominal heat output P
nom
18,7 kW ɻ
th,nom
93,3 %
Minimum heat output
(indicative)
P
min
4,9 kW ɻ
th,min
95 %
Auxiliary electricity consumption
Item Symbol Value Unit NO
At nominal heat output el
max
0,080 kW NO
At minimum heat
out
p
ut
el
min
0,060 kW NO
In standby mode el
sb
0,004 kW NO
NO
F(4)
0,9 % CC =2,5
yes
F (2) 7,0 % up to 2022
F (2) 0,0 % from 2022
NO
NO
with distance control option yes
F (3) 1,0 % up to 2022
F (3) 0,0 % from 2022
Contact details
Name and address of the manufacturer www.edilkamin.com
EDILKAMIN S.p.A. mail@edilkamin.com
Via Mascagni 7 Legal Representative
20045 Lainate (MI) – ITALY Paolo Gusella
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Type of heat output/room temperature control (select one)
Space heating emissions at nominal heat output Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
mg/m3 at 13%O2 mg/m3 at 13%O2
Energy Efficiency
Class
Characteristics when operating with the preferred fuel
Useful efficiency at nominal
heat output
Useful efficiency at minimum
heat output (indicative)
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus week
timer
9
ENGLISH
ECODESIGN TECHNICAL DATA
USER/INSTALLER
Manufacturer Edilkamin S.p.A.
Trademak Edilkamin
Model Identifier Blade H 22 Kira H 22 Vyda H 22
Description Mechanically space heater with boiler fired by wood pellets
Indirect heating functionality si
Direct heat output (space heat output) 2,5 kW
Indirect heat output (space heat output) 20 kW
CPR harmonised standard EN 14785
Notified Body Kiwa Cermet Italia (San Vendemiamo, Treviso, Italy) NB 0476
Fuel Preferred fuel
(unique)
PM OGC CO NOx PM OGC CO NOx
Compressed wood with moisture content < 12 % yes 14 2 147 123 21 3 93 114
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022 From 01/01/2022
ɻ
s
[%] 88,9 ɻ
s
[%] 81,9
EEI [%] 131 EEI [%] 124
Energy Efficiency Class A++ A+
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
BLF =1,45
F5 not of relevance
Heat output Useful efficiency (NCV as received)
Item Symbol Value Unit Item Symbol Value Unit
Nominal heat output P
nom
22,5 kW ɻ
th,nom
92,7 %
Minimum heat output
(indicative)
P
min
4,9 kW ɻ
th,min
95 %
Auxiliary electricity consumption
Item Symbol Value Unit NO
At nominal heat output el
max
0,080 kW NO
At minimum heat
out
p
ut
el
min
0,060 kW NO
In standby mode el
sb
0,004 kW NO
NO
F(4)
0,8 % CC =2,5
yes
F (2) 7,0 % up to 2022
F (2) 0,0 % from 2022
NO
NO
with distance control option yes
F (3) 1,0 % up to 2022
F (3) 0,0 % from 2022
Contact details
Name and address of the manufacturer www.edilkamin.com
EDILKAMIN S.p.A. mail@edilkamin.com
Via Mascagni 7 Legal Representative
20045 Lainate (MI) – ITALY Paolo Gusella
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus week
timer
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Type of heat output/room temperature control (select one)
Space heating emissions at nominal heat output Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
mg/m3 at 13%O2 mg/m3 at 13%O2
Energy Efficiency
Class
Characteristics when operating with the preferred fuel
Useful efficiency at nominal
heat output
Useful efficiency at minimum
heat output (indicative)
10
ENGLISH
UNPACKING-BRACKETS-FEET
INSTALLER
ADJUSTABLE FEET
The Blade H boiler stoves have adjustable feet to
adapt to uneven floors.
The feet can be adjusted by slightly raising the boiler
stove or using a screwdriver from above the foot.
feet
PREPARATION AND UNPACKING
The packaging materials are neither toxic nor noxious
The packaging materials are neither toxic nor noxious
and do not require special disposal. The user is
and do not require special disposal. The user is
responsible for storing, disposing of and recycling
responsible for storing, disposing of and recycling
them in conformity to the applicable laws.
them in conformity to the applicable laws.
PACKAGING
BLADE H STEEL
One item contains:
the stove structure;
the box with the steel claddings.
BLADE H CERAMIC
One item contains:
the stove structure;
a box with the metal parts;
two boxes strapped together each containing a
ceramic side panel.
Inside the product you will find: the warranty certificate,
this manual, power cable, two wall-mounting brackets.
The removable handle for opening the door is located
on the pallet.
Use appropriate equipment to shift the
product while keeping it in the vertical
position. Observe all applicable safety
regulations.
Take care not to tip the product.
TO REMOVE THE PALLET (ALL MODELS)
The stove is secured to the pallet with four brackets:
two at the front and two at the back.
Undo the two screws on each bracket
x 4
2 per side
WALL MOUNTING
Mount the stove to the wall with the plates provided
(a) and the brackets (b) already mounted on the
product, or use alternative systems that guarantee
that the product remains stable.
Fix the brackets to the wall using wall plugs.
a
The drawings are for guidance only, useful for
the installation, but they may not refer to the
specific model.
b
33
ENGLISH
FIRST IGNITION (COMMISSIONING) PHASES
Make sure you have read and understood this
manual.
Remove all flammable materials from the appliance
(manuals, labels, etc.). In particular remove any
labels from the glass.
Make sure the technician has carried out first
ignition for the product, and also filled the pellet
reservoir for the first time. Refer to the “Various
Menus” chapter under the “Pellet loading”
paragraph.
LOADING THE PELLETS INTO THE TANK.
To access the tank, open the lid.
*
When the boiler stove is hot, DO NOT
MAKE CONTACT between the pellet bag
and the top grille.
Use the glove when loading the stove while
it operates and is therefore hot to the touch.
Take care not to touch the fume exhaust
pipe when hot.
FUEL
Use Class A1 wood pellets conforming to the UNI
Use Class A1 wood pellets conforming to the UNI
EN ISO 17225-2 standard or similar local regulations
EN ISO 17225-2 standard or similar local regulations
envisaging, for example, products with the following
envisaging, for example, products with the following
characteristics:
characteristics:
diameter 6 mm
diameter 6 mm
length 3–4 cm
length 3–4 cm
humidity <10%
humidity <10%
For reasons of safety and environmental compatibility,
DO NOT burn, among other, plastic, painted wood,
coal or bark.
Do not use the stove as an incinerator.
Caution
Using fuels other than those specified can
damage the appliance.
INTRODUCTION ABOUT USE
When ignited the first few times, there
may be a slight smell of paint which will
disappear in a short time.
USER
VENT
During normal operations the vent
is automatic. During installation, the
technician must check the efficiency of the
automatic vent (located beneath the upper
grille) and assess whether a manual vent
needs to be installed.
automatic vent
upper grille removed
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Blade H - EKleaner at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Blade H - EKleaner in the language / languages: English as an attachment in your email.

The manual is 3.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Blade H - EKleaner

Edilkamin Blade H - EKleaner Usermanual and installation guide - German - 52 pages

Edilkamin Blade H - EKleaner Usermanual and installation guide - Dutch - 52 pages

Edilkamin Blade H - EKleaner Usermanual and installation guide - French, Italian - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info