ENGLISH
INSTALLER
INSTALLATION
NOTE
The flue outlet Ø is not that of the chimney system, which must be sized in accordance with
national and local standards and in particular, but not limited to, EN 13384, EN 1443, EN
1856, EN 1457.
REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Note that:
Note that:
The appliance may only be installed by a qualified
The appliance may only be installed by a qualified
technician authorised to issue the declaration of
technician authorised to issue the declaration of
conformity.
conformity.
The appliance must be installed and operated
The appliance must be installed and operated
in compliance with local and national law and
in compliance with local and national law and
European regulations. The applicable Italian
European regulations. The applicable Italian
regulation is UNI 10683.
regulation is UNI 10683.
If installed in a condominium, the appliance must
If installed in a condominium, the appliance must
be approved by the administrator.
be approved by the administrator.
We give some general instructions below, however
We give some general instructions below, however
these do not obviate the need to comply with local
these do not obviate the need to comply with local
regulations and do not affect the installer’s liability for
regulations and do not affect the installer’s liability for
the installation.
the installation.
Checking the suitability of the installation
space
The room must have a volume of at least 20 m3
The floor must be able to bear the weight of the
product and its accessories.
Level the appliance
The appliance may not be installed in a bedroom,
bathroom or in the same room as other equipment
which draws air for combustion from the room
itself, or in any area with an explosive atmosphere.
Any extraction fans operating in the same room or
area as the product, may affect its draw.
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas fired
products.
Levelling feet
The product has 6 feet (3 at the front and 3 at the back)
which can be adjusted with a screwdriver from inside
the appliance BEFORE the cladding is fitted.
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The product must be installed in observance of the
following safety instructions:
- minimum clearance at the sides and back of 10 cm
from flammable materials.
If the material is not flammable, the minimum
clearance is provided by the wall-mounting brackets
(pre-installed).
- no flammable materials may be kept closer to the
front of the appliance than 80 cm.
If connected to a wooden or otherwise flammable wall,
the flue must be insulated appropriately.
If installed on a flammable or combustible floor, or
which is not capable of bearing its load, use steel or
glass plates under the stove to distribute the load.
Contact the retailer for such optional equipment.
Positioning the product
The product is designed to operate in all climatic
conditions. In special circumstances, such as strong
wind, its safety equipment may switch the stove off.
Contact the authorised Edilkamin Technical Assistance
Centre.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Blade 2 - 12 Up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Blade 2 - 12 Up in the language / languages: English as an attachment in your email.

The manual is 5.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Blade 2 - 12 Up

Edilkamin Blade 2 - 12 Up Usermanual and installation guide - German - 68 pages

Edilkamin Blade 2 - 12 Up Usermanual and installation guide - Dutch - 72 pages

Edilkamin Blade 2 - 12 Up Usermanual and installation guide - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info