The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the thermal stoves?
Smoke outlet that is at least 100 mm in diameter.
An air inlet in the room that is at least 80 cm².
¾” G outlet and inlet fitting.
¾” G drains connection for overpressure valve.
¾” G load fitting.
A certified electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the thermo-stoves work without water?
NO. Using the thermo-stoves without water will damage it.
3) Do thermal stoves emit hot air?
NO. Most of the heat is transferred to the water.
Only Quebec / Toronto / Montreal / Detroit / Boston / Miami emit a small amount in the installation environment in the form of radia-
tion from the glass hearth. It is advisable in any case to use a radiator in the same room.
4) Can I connect the inlet and outlet of the thermo-stoves directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do thermal stoves also supply hot sanitary water?
It is possible to produce domestic hot water using the KIT built in to the stove, this is an instantaneous production without accumula-
tion.
6) Can I discharge the smoke from the thermal stoves along the wall?
NO, a discharge which is conform with standards (UNI 10683) must reach the ridge of the roof, and in any case proper functioning
requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke forms in the
installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the thermo-stoves for combustion. The smoke extractor draws the air from the room into the combu-
stion chamber.
8) What settings are required on the thermo-stoves display?
The desired water temperature. The thermo-stoves will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the thermo-stoves accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the thermo-stoves is not used for some time.
10) Can I burn other fuel apart from pellets?
NO. The thermo-stoves has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.
11) Can I ignite the thermo-stoves by sending an SMS?
Yes, if the DEALER or an electrician has installed the connection via an optional cable code 640560 to the serial port behind the ther-
mo-stoves
FAQ
GlassKamin
(code 155240)
Used for cleaning the
ceramic glass
Ash vacuum cleaner
without motor
(code 275400)
User for cleaning the
hearth
CLEANING ACCESSORIES (optional extras)
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin ATLANTA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin ATLANTA in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info