810884
18
Zoom out
Zoom in
Previous page
1/36
Next page
18
ENGLISH
LED FAULTS CAUSES REMEDY
Lights up red
Blocking Rotor blocked Activate manual restart or
contact customer service
Contacting/ winding Winding defective
Flashes red
Under/
overvoltage
Power supply too low/
high on mains side
Check mains voltage and
operating conditions, and
request customer service
Excessive temperature
of module
Module interior too
warm
Short-circuit Motor current too high
Flashes red/ green
Generator
operation
Water is flowing through the
pump hydraulics, but there is
no mains voltage at the pump
Check mains voltage,
flow rate/ pressure and
ambient conditions
Dry run Air in the pump
Overload
Sluggish motor, pump is
operated outside of its
specifications (e.g. high
module temperature).
The speed is lower than
during normal operation.
FAULT SIGNALS
• The fault signal LED indicates a fault.
• The pump switches off (depending on the fault) and attempts a cyclical restart.
MANUAL RESTART
The pump attempts an automatic restart upon detecting a
blockage. If the pump does not restart automatically:
Activate manual restart via the operating button: press and
hold for 5 seconds, then release.
• The restart function is initiated, and lasts max. 10 minutes.
• The LEDs flash in succession clockwise.
To cancel, press and hold the operating button for 5 seconds.
NOTICE
After the restart, the LED display
shows the previously set values of
the pump.
PUMP: INSTALLATION AND OPERATING INSTRUCTIONS
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin ATLANTA UP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin ATLANTA UP in the language / languages: English as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin ATLANTA UP

Edilkamin ATLANTA UP Usermanual and installation guide - German - 36 pages

Edilkamin ATLANTA UP Usermanual and installation guide - Dutch - 36 pages

Edilkamin ATLANTA UP Usermanual and installation guide - French, Italian - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info