810821
30
Zoom out
Zoom in
Previous page
1/200
Next page
- 30 -
ENGLISH
GENERAL INFORMATION
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali¿ ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a UPS of at least 800
Vac. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi¿ cation on the part of the noti¿ ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de¿ ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insuf¿ cient for it to function correctly.
• PELLET HOPPER MICRO-SWITCH
A micro-switch placed on the external door B of the pellet hopper will shut down the stove in case the doors A and B are not total-
ly closed
THERMO TECHNICAL CHARACTERISTICS according to EN 14785 (for other values, see DoP on page 31)
Nominal power Reduced power
Thermal power output 8 2,4 kW
Yield / Ef¿ ciency 90,1 91,8 %
Emissions CO 13% O2 0,008 0,044 %
Fume temperature 122 60 °C
Fuel consumption 1,8 0,5 kg/h
Hopper capacity 20 kg
Draught 12 - 5 10 - 3 Pa
Autonomy 9 34 hours
Heatable volume * 210 m3
Smoke outlet pipe diameter (male) 80 mm
Air intake pipe diameter (male) 40 mm
Weight including packaging (steel/glass) 182 / 200 kg
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Nominal power Reduced power
Thermal power output 8 2,4 kW
Temperature of fumes on exit from the discharge pipe 146 72 °C
Minimum draught 0-5 Pa
Fume À ow capacity 6,9 4 g/s
Classi¿ cation of combustion chamber according to DIBt FB 22 FC52x -
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
ELECTRICAL CHARACTERISTICS
Power supply 230 Vac +/- 10% 50 Hz
Average power consumption 120 - 150 W
Power consumption during ignition 400 W
Remote control frequency 2,4 GHz
Protection on electronic circuit board T2A, 250 Vac, 5x20 Fuse
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Ania Air Tight at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Ania Air Tight in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Ania Air Tight

Edilkamin Ania Air Tight User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info