SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
55
decreasing current ensures that the terminal voltage does not become too high during
the complete charging process.
FLOAT (charge maintenance): The battery status remains permanently at 13,8 V*
without overcharging or damaging the battery. The voltage is permanently controlled in
this mode. If the voltage decreases to a predefined level, the battery is charged through
a pulse charge until reaching again 100%, so the charge status remains permanently
between 95% and 100%. This charging-cycle is repeated appropriately and influences
the lifetime of the battery in a positive way.
* All voltage values refer to 12 V. For 24 V: double value, for 48 V: quadruple value.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ective Energy SSI304 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ective Energy SSI304 in the language / languages: English, German as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info