660286
56
Zoom out
Zoom in
Previous page
1/68
Next page
[
ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
54
Functional diagrams of charger/MPPT-solar
charge controller
G
eneral information about charging function
Device switched on:
in Inv. mode (pure inverter mode):
only solar power is used to charge the batteries.
only solar power is used to supply the 230 V consumers.
in UPS mode (uninterruptible power supply):
Solar power is primarily used to charge the batteries.
Shore power is primarily used to supply 230 V consumers.
If solar power is disconnected or it becomes dark, the system switches from solar to
AC charging via shore power after approx. 30 seconds.
Device switched off:
Si
multaneous charging with solar and shore power possible
(like scenario 5, see from page 56).
Explanation of charging phases CSI- and SSI-series
The integrated charger as well as the MPPT-solar charge controller of the SSI-series
charge automatically with a 3-step IUoU charge characteristic which is described on the
following page.
Bulk (main charge): The battery is charged with permanent current and carefully rising
voltage until a predefined maximum voltage and until a stage of charging of 80% is
reached.
Absorption (remaining charge): The battery is charged with permanent current and
gradual decreasing current from 80% to 14,4 V* and a 100% capacity. The gradual
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ective Energy CSI304 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ective Energy CSI304 in the language / languages: English, German as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info