796755
30
Zoom out
Zoom in
Previous page
1/304
Next page
30
EN
No. Problem Possible cause Solution
3
AIRBOT is having trouble
returning to the Charging
Dock.
The Charging Dock is out of power. Make sure that the Charging Dock is fully connected to
the power.
The Infrared Anti-collision Bumper and
Charging Dock Signal Sensor is blocked by
dirt or debris.
Wipe the Infrared Anti-collision Bumper and Charging
Dock Signal Sensor with a soft cotton cloth if there is
any dirt or debris..
4
AIRBOT returns to the
Charging Dock before the
purification is completed.
AIRBOT automatically returns to the
Charging Dock when the battery is low.
This is normal behaviour. When AIRBOT is not working,
keep the Charging Dock plugged in and keep AIRBOT
powered ON and on the Charging Dock to make sure
it has a full battery.
AIRBOT needs to recharge because the
complex home environment may reduces
purification efficiency.
Tidy up the furniture and the objects on the floor as
described in Section 3.
5 AIRBOT is not charging.
The power adapter has not made a
connection with the power cord.
Please make sure the power adapter is fully connected
with the power cord.
AIRBOT has not made a connection with
the Charging Dock.
Be sure that the Charging Contacts on AIRBOT have
made contact with the Charging Contacts on Charging
Dock. You can move AIRBOT manually to make the
connection if necessary.
The Charging Contacts are covered with
dirt. Clean the Charging Contacts according to Section 4.
The Charging Dock is on the carpet. Place the Charging Dock properly according to Section
3.1.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecovacs AIRBOT Z1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecovacs AIRBOT Z1 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 19.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info