Chapter A — Specifications
86
Imager Reading Distances
The guaranteed depth of field measurements were taken using these
parameters:
• Distances are measured from the front of the engine.
• 23 °C (73 °F), 0 lux
• Photographic quality codes
Note: Time to Read and Depth of Field are impacted if the bar code
symbol is at the edge of the image.
White Illumination Monochrome Sensor Only - Guaranteed Specs
Focus Standard Range (SR)
Symbology Near Distance
(in/cm)
Far Distance
(in/cm)
Delta
(in/cm)
5 mil Code 39/128 3.6 (9.1) 5.6 (14.2) 2.0 (5.1)
10 mil Code 39/128 1.9 (4.8) 12.0 (30.5) 10.1 (25.6)
100% UPC 2.1 (5.3) 15.1 (38.1) 12.9 (32.7)
6.7 mil PDF 417 2.5 (6.4) 6.6 (16.7) 4.1 (10.4)
10 mil DataMatrix/Aztec 2.9 (7.4) 7.3 (18.5) 4.4 (11.1)
White Illumination Monochrome Sensor Only - Typical Specs
Focus Standard Range (SR)
Symbology Near Distance
(in/cm)
Far Distance
(in/cm)
Delta
(in/cm)
5 mil Code 39/128 2.5 (6.4) 6.4 (16.3) 3.9 (9.9)
10 mil Code 39/128 1.1 (2.8) 13.0 (33.0) 11.9 (30.2)
100% UPC 1.8 (4.6) 16.5 (41.9) 14.7 (37.3)
6.7 mil PDF 417 1.8 (4.6) 7.3 (18.5) 5.5 (14.0)
10 mil DataMatrix/Aztec 2.1 (5.3) 8.0 (20.3) 5.9 (15.0)