32
pipe
.
Air distribution group. RECOMMENDABLE
In case of excessive load loss / pipe lengt
(Ductable stoves).
Ø60
pipe
. resistant to constant
temperatures of 120 °C
OBLIGATORY Teide model. Connection for lateral convectors.
LOCATION AND SAFETY DISTANCES.
4.11. Do not install the stove in a sleeping room.
4.12. Install a fire protection between the ground and the stove if the floor is a combustible material.
4.13. Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Ensuring a
better access to the stove for future maintenance or repair work is also worth considering.
Drawing 5
INSTALLATION OF BUILT-IN STOVES
The measurement of the lateral ventilation openings indicates the effective area of air passage through
them. If a decorative grid is placed, the effective area of air passage of the said grid must coincide with the effective
area of passage of the openings, varying the dimensions (height and / or width) of the grids to achieve the right air
passage area.
Figure 7 shows the minimum permitted dimensions of the built-in space (non-flammable material) with
respect to the stove and the position of the ventilation grids, for the installation of the Córdoba, Córdoba ducted,
Teide and Granada models.
B
-
B SECTION
C
-
C SECTION
Drawing 6
A
Lateral wall.
≥ E
B
Back of the
stove
. Minimum
separation that allows visualizing the
label marking the stove.
≥ 80 mm
C
1.5 x de
pth of stove.
See dimensions
D
Shelf
.
≥ 600 mm
E
Depth of
stove.
See dimensions

Effective grid area left side.
OBLIGATORY.
≥ 200x120mm

Effective grid area right
.
OBLIGATORY.
≥ 200x120mm

Isolated output gas pipe within the
socket. OBLIGATORY.
Ø80mm

Thermally insulated convection air
ducting. OBLIGATORY.
Ø100mm
50
50
B
C
C
B
B
B
C
C
50
50
2
4
3
1
0
2
>
2
0
0
>
1
2
0
>
2
0
0
2
0
5
>
1
2
0
2
4
0
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Paris at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Paris in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 9,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info