815579
37
Zoom out
Zoom in
Previous page
1/144
Next page
36
Drawing 14
4.28. Installing a fitted stove in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 15. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
Drawing 15
When installing a flexible tube for gas outlet, be careful that this is not in contact or close to the circuit board
or combustible material.
DUBAI, IBIZA, VENECIA, BOSTON Y KIEV MODELS.
Convection air must always travel through insulated pipelines.
The maximum length for all pipes channeling air is of 7 meters. If the user needs longer pipes, he/she must
install an additional ventilation motor (see the diagram detailing the different parts).
Stove models Venecia and Ibiza have Ø116cm supply air duct systems. If the user choses not to channel
convection air through a pipeline, the supply air duct system () can be replaced for direct vertical exits () (see
drawing 16). To better access the supply air duct system, we recommend removing the top grid (fastened with 4
screws, one at each corner.

Stainless steel hose clamp.

T of 90° with outlet.

Wooden ground.

Non flammable floor protection.

Isolated stainless steel flexible tube.

Rigid flexible pole adapter.

Minimum 200mm.

It must exceed roof height by 1 metre.

If the tube over 8 m in length, the next larger
size will be used.

Stainless steel hose clamp.

T of 90° with outlet.

Wooden ground.

Non flammable floor protection.

Stainless steel flexible tube.

Rigid flexible pole adapter.

Anti blow-back seal.

Minimum 200mm.

It must exceed roof height by 1 metre.

If the tube over 8 m in length, the next larger
size will be used.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Ibiza at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Ibiza in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 6.29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ecoforest Ibiza

Ecoforest Ibiza User Manual - English, German, Dutch, French, Italian, Portuguese, Spanish - 228 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info