Burn pot.

Segurity grill of the fireplace.

Ash box.
Drawing 20
IMPORTANT
: If the stove is operating while full of ash or residues, that might stretch the burn pot and its
support, the ash box and even the burn pot, being the cause of bad operation or possible breakdown.
MAINTENANCE AT END OF SEASON OR EVERY 500 KG OF FUEL.
This is necessary to ensure correct operation and maintain the stove’s life duration. When winter ends,
contact your provider (if he did not contact you) and meet to carry out this maintenance; the following shall be done
(the stove must always be disconnected from power):
5.4. Review of the daily and weekly cleaning outlets.
5.5. Cleaning outlets. The cleaning outlet lids are marked in red.
The Paris and London models has 5 cleaning hatches, which are accessible on the front of the stove (3
hatches), by removing the grate, as in drawing 21. The London model has the same registers as the Paris
model, but to access the fronts the complete burning pot must be removed. The 2 remaining hatches are in
the convection chamber, which is accessed by opening the corresponding side door and removing the
convection chamber plate as shown in drawing 22.
To access the cleaning registers for the Córdoba, Granada and Teide models, we must also unblock the
guides to reach the cleaning registries. To do this, we must remove the housing door disassembling this from
its hinges, and later lowing until the door comes free from the lower bolt. With the door removed, we will
now have access to the guides (drawing 24). Warning! Please handle the door carefully to avoid any
blemishes on the glass ceramic hob.
There are outlets in both sides of the stoves, and a larger one on the front of stoves (drawing 25). In
drawings are only represented these ones of the right side.
Model Praga (drawing 26): to remove the side covers, it is necessary to loosen and remove 4 screws, 2 in the
back, 1 below the hopper lid and 1 in the lower part, behind the hearth door.
The Tokio, Córdoba, Teide, Granada and Praga models have also 4 inspection covers in the stove’s hearth.
See drawing 27 (Tokio).
Drawings 28 and 29 correspond to model Tokio.
Models ECO III and ECO III insert have 3 cleaning outlets. One is located right at the front and is accessible
when removing the lower trim cover (drawing 30) and then there is one on each side. To access the lateral
outlets (drawings 30 and 31) of model ECO III, the user must open the side doors and remove the right-hand
column, which only has an aesthetic purpose. The outlets in model ECO III insert are the same.
The Bolonia model has 2 cleaning windows, one on the right side and the other in the back (figure 32).
Once we have access to these outlets, we have to clean them thoroughly (using the wire brush that was
supplied together with the stove and a vacuum cleaner). The proper functioning of the stove will depend on
its cleaning.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Granada at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Granada in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 9,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ecoforest Granada

Ecoforest Granada User Manual - English, German - 228 pages

Ecoforest Granada Installation Guide - Dutch - 208 pages

Ecoforest Granada User Manual - Dutch, French, Italian, Portuguese, Spanish - 228 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info