742220
32
Zoom out
Zoom in
Previous page
1/152
Next page
31
4.9. If our model has a plastic protection, it must be removed before starting it.
4.10. Remove the protection of the exhaust gas fan and the convector in the case of ductable stoves.
To remove the gas output cover in models with option for top output, it is necessary to access the inside of
the stove to remove the cover nuts.
Drawing 3 Drawing 4
MATERIAL REQUIRED FOR INSALLATION.
MATERIAL
COMPLIANCE
PARTICULARS
It will be made of a material
resistant to the aggressive action
of the combustion products, to
condensation and to constant
temperatures of 300 °C. The
material will comply with the
local legislation for its
application.
OBLIGATORY
ALL.
Aluminum, galvanized or iron
pipe.
PROHIBITED
ALL.
Insulated double wall pipe.
OBLIGATORY
Proximity to flammable materials.
When crossing a forge or partition.
Outdoor or brick-built chimney installation.
Insert stoves. See figure 7.
RECOMMENDABLE
Relative ambient humidity ≥ 60%.
Installation in a public facility.
Potentially accessible to children or people with
mental, physical or sensory disabilities.
Elbow Ø80 X 45° OBLIGATORY
London Model. Exhaust gas connection.
Elbow Ø80 X 90° OBLIGATORY
Tokio and Bolonia models. Exhaust gas outlet
with rear connection
T with outlet. OBLIGATORY
ALL.
Clamp union. OBLIGATORY
Install the exhaust spiral and gas outlet pipes,
thereby preventing anyone from disassembling
or moving the stove or pipe without tools.
Pipe anchors. OBLIGATORY
Install the pipe, thereby preventing anyone from
disassembling or moving the stove or pipe
without tools.
Aluminium belt and silicone of
high temperature (300°C).
RECOMMENDABLE
If the pipe is not equipped with sealing rings
Ventillation grills.
OBLIGATORY
Insert stoves.
S
ee figure 7.
Thermally insulated extensible
OBLIGATORY
Ducting of convection air (Ductable stoves
).
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Granada at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Granada in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 9,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ecoforest Granada

Ecoforest Granada User Manual - English, German - 228 pages

Ecoforest Granada Installation Guide - Dutch - 208 pages

Ecoforest Granada User Manual - Dutch, French, Italian, Portuguese, Spanish - 228 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info