815608
48
Zoom out
Zoom in
Previous page
1/228
Next page
47
CPU Serial number
CPU Serial number, also written in the label of the CPU.
It varies depending on
CPU.
Software version
CPU Software version
It varies depending on
the CPU.
Fuel
Pellet
Pellet, olive pit, almond
shell.
Water pressure
Water pressure in the hydraulic circuit (only water
models).
Water pressure in bars
5.5. OPERATING MODES.
To access this menu the stove must be turned off and showing no alarm (status 0).
The characteristics of the operating modes are set out below.
TYPE OF APPLIANCE
AIR (STOVE)
WATER (BOILER /HYDROSTOVE)
POWER
Default configuration.
Manual power management.
Power level modifiable from keyboard, web or
calendar set.
9 power levels, 9 being the maximum level.
Default configuration.
Monozone; Room T. = 21 ° C; Heating drive = 65
° C; T. Stand-by = 82 °C
Manual power management.
Power level modifiable from keyboard, web or
calendar set. 9 power levels, 9 being the
maximum level.
If the demand of the control terminal (room
probe, thermostat or THT) or the water supply
has been satisfied, it will reduce power to the
minimum level.
Room temp. regulation range between 12 ° C
and 40 ° C.
Possibility of managing on and off, according to:
Control terminals.
Buffer sensors.
TEMPERATURE
Automatic power management.
According to demand of the control terminal
(room probe, thermostat or THT):
Instantaneous power level.
On and off (configurable).
Room temperature regulation range between
12 ° C and 40 °C.
Automatic power management.
According to the supply temperature and the
demand of the control terminal (room probe,
thermostat or THT).
Possibility of managing on and off, according to:
Control terminals.
Buffer sensors.
Ambient regulation range between 12 ° C and
40 °C.
To select the temperature mode, set the operation mode.

Operating mode selection.

Access to settings.

Password. (Technical assistance)

Validate access.
Drawing 36
Power
Temperature
User:
Password:
SETTINGS SEND
MODE LOGIN
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Fortaleza at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Fortaleza in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 19.61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ecoforest Fortaleza

Ecoforest Fortaleza Installation Guide - French, Spanish - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info