782441
26
Zoom out
Zoom in
Previous page
1/100
Next page
E93.0901NL Handleiding Consul+
26
6.6.2 VIER VOORBEELDEN VAN ROOKGASPIJP BEREKENINGEN.
Hierna volgen vier voorbeeldcalculaties voor het bepalen van de weerstand van het rookgaskanaal en de luchttoe-
voerleiding, met behulp van de gegeven tabel.
A: Systeem met losse rookgasafvoer en luchttoevoer
B: Systeem met losse rookgasafvoer / luchttoevoer en concentrische dakdoorvoer
C: Losse rookgasafvoer (luchttoevoer vanuit de ketel ruimte)
D: Concentrisch met dakdoorvoer
6.6.3 VOORBEELD A: PARALLEL SYSTEEM (C63)
Rekenvoorbeeld met gegeven lengtes: controleren van de weerstand
De totale weerstand is minder dan 100 Pa, dit rookgasafvoer/luchttoevoer
systeem is functioneel.
Ketel type:
Consul+35
Rookgas
Diameter: 80 mm
Aantal
Pa
Pa totaal
Rechte leiding m¹
totaal
9
4
36,0
Bocht 90° 2 4 8,0
Rookgas uitlaat
Conisch
1
0,2
0,2
Totale weerstand rookgasafvoer:
44,2
Lucht
Diameter: 80 mm
Aantal
Pa
Pa totaal
Rechte leiding m¹
totaal
8
3
24,0
Bocht
90°
2
3
6,0
Luchtinlaat H/D = 1,0 1 4 4,0
Totale weerstand luchttoevoer:
34,0
Totale weerstand rookgasafvoer en luchttoevoer: 78,2
6.6.4 VOORBEELD B: PARALLEL SYSTEEM MET CONCENTRISCHE DAKDOORVOER (C33).
Ketel type:
Consul+55
Rookgas
Diameter: 80 mm Aantal Pa Pa totaal
Rechte leiding m¹ totaal 6 5,3 31,8
Bocht 90° 2 5,3 10,6
Totale weerstand rookgasafvoer:
97,4
Lucht
Diameter: 80 mm Aantal Pa Pa totaal
Rechte leiding m¹ totaal 6 4,1 24,6
Bocht
90°
2
4,1
8,2
Totale weerstand luchttoevoer: 32,8
Dak uitlaat.
conc.
80/125
1 55 55,0
Totale weerstand rookgas afvoer en lucht toevoer:
130,2
De totale weerstand is minder dan 170 Pa, dit rookgasafvoer/luchttoevoer
systeem is functioneel.
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
5 m
4 m
2 m
2 m
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eco Heating Systems Consul plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eco Heating Systems Consul plus in the language / languages: Dutch as an attachment in your email.

The manual is 3.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info