782443
64
Zoom out
Zoom in
Previous page
1/120
Next page
E93.1001NL.E Handleiding CD+
64
10.9 Instellingen
In de hierna volgende beschrijving worden de warmwaterinstellingen behandeld.
Tapwatertemperatuur normaal bedrijf/dag: (P4 AA = 1/2)
W
W
I
n
s
t
e
l
l
i
n
g
6
0
°
C
Dit is de tapwatertemperatuurinstelling, die actief is tijdens
de ingestelde tapwaterperioden.
Tapwatertemperatuur nachtverlaging: (P4 AA = 1/2)
W
W
n
a
c
h
t
v
e
r
l
a
g
i
n
g
1
0
°
C
Dit is de warmwater nachtverlaging t.o.v. de normaal be-
drijf/dag-instelling, die actief is buiten de geprogram-
meerde tapwaterperioden.
Aanvoer watertemperatuur uit toestel:
(P4 AA = 2, P5 DJ & DK = 1)
C
V
I
n
s
t
e
l
l
i
n
g
7
5
°
C
Dit is de watertemperatuurinstelling lokaal op de aanvoer-
sensor S1 van het toestel.
10.10 Instellen van de klok programma’s
De ketel heeft twee instelbare programma’s:
warmwater programma
antilegionella programma
STARTEN MET PROGRAMMEREN
Per dag kunnen 3 perioden worden geprogrammeerd (periode 1, 2 en 3). Tijdens deze perioden gebruikt de ketel
de normale warmwaterinstellingen. Buiten deze perioden zijn de verlaagde temperatuurinstellingen actief. Als geen
tijd is geprogrammeerd, wordt de betreffende periode overgeslagen.
(Voorbeeld maandag periode 3 geen tijd geprogrammeerd > "Maa 3 --:-- ---:--")
Bedieningsscherm:
T
A
P
W
V
d
:
K
e
t
e
l
u
i
t
>
>
>
:
1
2
3
.
4
°
C
(
1
2
3
.
4
°
C
)
Druk op [MENU]
Kies "Programma" met [◄] & [►] en druk op [ENTER]
Hoofdmenu scherm:
H
o
o
f
d
m
e
n
u
P
r
o
g
r
a
m
m
a
Druk op [ENTER]
Programmatijden instellen:
P
r
o
g
r
a
m
m
a
C
V
M
a
a
1
0
6
:
0
0
-
2
3
:
0
0
Druk op [] voor het volgende SCHERM
> > > vervolg op volgende bladzijde met WARM TAPWATER deel < < <
LET OP:
De waarde bij: “CV instelling”
dient altijd gelijk of hoger te zijn
dan het setpoint ingesteld bij
“WW instelling” De “CV instel-
ling” is de maximaal mogelijke
wateraanvoer temperatuur van
de ketel naar de tank.
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eco Heating Systems CD plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eco Heating Systems CD plus in the language / languages: Dutch as an attachment in your email.

The manual is 3.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info