10 E93.9950NL CB Cascade manual
Aantal ketels
(tot 360 kW)
2 ketels 3 ketels 4 ketels
L1 (lengte frame)
1030
1520
2010
L2 (totale lengte incl. open verdeler) 1428 1918 2408
L3 (lengte open verdeler)
422
422
422
H1 (hoogte gas aansl.)
308
308
308
H2 (hoogte verdelerpijp koppeling)
248
248
248
H3 (hoogte koppelingen)
350
350
350
D1 (verdeler aansluitmaat)
DN 65 PN6 (2½ “)
DN 65 PN6 (2½ “)
DN 65 PN6 (2½ “)
D2 (verdeler aansluitmaat)
DN 65 PN6 (2½ “)
DN 65 PN6 (2½ “)
DN 65 PN6 (2½ “)
D3 (gas aansluitmaat) R 2” R 2” R 2”
A (gas)
253
253
253
B (verdelers)
459
459
459
Tabel 4.1 Afmetingen CB cascade tot 360 kW
Aantal ketels
(360 tot 540 kW)
3 ketels 4 ketels
L1 (lengte frame)
1520
2010
L2 (totale lengte incl. open verdeler)
1938
2473
L3 (lengte open verdeler)
487
487
H1 (hoogte gas aansl.)
308
308
H2 (hoogte verdelerpijp koppeling)
257
257
H3 (hoogte koppelingen) 380 380
D1 (verdeler aansluitmaat)
DN 80 PN6 (3 “)
DN 80 PN6 (3 “)
D2 (verdeler aansluitmaat)
DN 80 PN6 (3 “)
DN 80 PN6 (3 “)
D3 (gas aansluitmaat) R 2” R 2”
A (gas)
253
253
B (verdelers)
466
466
Tabel 4.2 Afmetingen CB cascade 360 tot 540 kW
Aantal ketels
(540 to 930 kW)
4 ketels 5 ketels 6 ketels
L1 (lengte frame)
2010
2500
2990
L2 (totale lengte incl. open verdeler)
2614
3104
3594
L3 (lengte open verdeler)
628
628
628
H1 (hoogte gas aansl.)
327
327
327
H2 (hoogte verdelerpijp koppeling)
272
272
272
H3 (hoogte koppelingen) 420 420 420
D1 (verdeler aansluitmaat)
DN 100 PN6 (4 “)
DN 100 PN6 (4 “)
DN 100 PN6 (4 “)
D2 (verdeler aansluitmaat)
DN 100 PN6 (4 “)
DN 100 PN6 (4 “)
DN 100 PN6 (4 “)
D3 (gas aansluitmaat) DN 80 (3”) DN 80 (3”) DN 80 (3”)
A (gas)
253
253
253
B (verdelers)
482
482
482
Tabel 4.3 Afmetingen CB cascade 540 tot 930 kW
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eco Heating Systems CB-CH series Cascade at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eco Heating Systems CB-CH series Cascade in the language / languages: Dutch as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info