16
ENGLISH
PLEASE NOTE: SH12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR THE MOST UP TO DATE WARRANTY AND MANUAL.
materials. A minimum clearance of 6”(15.2cm) between the vent pipe and ceiling should be maintained.
Follow local codes.
For maintenance and inspection purposes, the
following holes are required to be made:
• Two (2) inspection openings that allow access to
venting. One (1) of these openings should be close
to where the vent pipe enters the ceiling. The other
opening should be near the vent termination.
• A ventilation hole with a 16 sq. in.(103cm²) opening
should be made at least every 10 ft.(3m).
NOTICE : Vent pipes must be completely insulated
closets, and garages and must not touch any
The water heater must be vented to the outdoors. Termination must be 50 cm away from any
obstructions and the termination must be at least 5 cm away from the wall, as described in these
or ducts with internal plastic coatings.) It is recommended to use included venting. Refer to your local
municipality if additional venting is needed.
The included vent termination should be used. If not, a termination hood with a screen must be used.
(Refer to page 19). Do not remove the terminal guard. The terminal outlet must not be covered by
anything.
Use a vent pipe with an antidisconnection
structure. The use of a High Temperature
Silicone (500° F, 260°C) may be required to seal
vent connections. To prevent accidental gas
another bead against the joint side of the stop
bead.
Follow vent manufacturer’s installation instructions. The water heater can be vented either horizontally
or vertically.
Vent pipe runs must be adequately supported along both horizontal and vertical runs.
WARNING: Refer to pages 9-11 for clearances from combustible materials.
Venting
INSTALLATION
*Use Proper Support Straps
NO YES
DANGER: Failure to install the vent adapter and properly vent the water heater to the outdoors as
outlined in the Venting section of this manual will result in unsafe operation of the water heater causing
proper operation as outlined in the Venting section of this manual.
(15.2cm)
(61cm)
(.6 cm) (.3m)
(25 cm) (25 cm)
10" 10"
Typical Horizontal Termination
w/ 1/4"(.6cm) per foot(.3m)
UPWARD Slope
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp SH12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp SH12 in the language / languages: English as an attachment in your email.

The manual is 4.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eccotemp SH12

Eccotemp SH12 User Manual - German - 39 pages

Eccotemp SH12 User Manual - Dutch - 39 pages

Eccotemp SH12 User Manual - French - 39 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info