PLEASE NOTE: FVI12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
English
Setting the Temperature:
The Eccotemp FVI12-LP/NG models are MANUAL TEMPERATURE CONTROLLED units. This means
that the temperature must be adjusted on the face plate of the unit and not at the output source
(sink or shower).
When you try to mix hot water with cold at the output source, the heater will shut down because
as you mix in the cold water, you are decreasing the amount of required water pressure to keep
the unit activated. The FVi12 is a pressure activated unit and should maintain at least 40-60 PSI of
water pressure. When cold water is added, the pressure drops below the activation point.
Manual Temperature Control: You must adjust the
temperature manually each time you use the unit. The
temperature must be adjusted according to the amount
of applications being used at the same time due to the
uctuation of pressure.
NOTICE: If inlet water temperature is high, and set
temperature is low, the actual temperature might be higher
than the set temperature, and viceversa..
DANGER: There is a hot water
scald potential if the temperature
is set too high. Households with
small children, disabled, or elderly
persons may require a 120°F or
lower temperature setting to
prevent contact with HOT water.
Output temperature of water is regulated by
setting the temperature on the front of the unit.
Safety factors should be considered when
selecting the water temperature.
Water temperature above 120°F can cause severe
burns or death from scalding. The thermostat is
adjusted to its lowest temperature position when
shipped from the factory.
Be sure to read and follow the warnings outlined
in this manual and on the label located on the
water heater. Mixing valves are available for
reducing point of use water temperature by
mixing hot and cold water in branch water lines.
Procedures for adjusting the thermostat for
energy e cient operation at the minimum
water temperature setting consistent with the
consumers needs.
Contact a licensed plumber or the local plumbing
authority for further information. See page 4 for
details.
Water Temperature
120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Table courtesy of Shriners Burn Institute
Automatic Temperature Control: The unit will self-adjust
temperature according to what is being requested of
it at the output water source (sink or shower). It also will
regulate the temperature automatically according to
how many applications are being used at the same time.
WARNING: Should overheating occur or the gas supply fail to shut o , turn o the
manual gas control valve to the water heater.
NOTICE: If the BATH control ls turned on, the temperature setting on the MAIN control
cannot be changed. The BATH control(s) will always have PRIORITY over the MAIN control.
Automatic vs. Manual Temperature Control
Water Temperature
Operating
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp FVI-12 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp FVI-12 series in the language / languages: English as an attachment in your email.

The manual is 5.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info