782659
46
Zoom out
Zoom in
Previous page
1/56
Next page
43
PLEASE NOTE: EL22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND EL22-I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
English
Properly maintained, your water heater
will provide years of dependable
trouble-free service. It is recommended
that a periodic inspection of the burner,
relief valve, water lter and venting
system should be made by service
personnel qualied in gas appliance
repair.
It is suggested that a routine preventive
maintenance program be established
and followed by the user.
At least once a year, lift and release the
lever handle on the pressure relief valve,
located in the hot outlet piping of the
water heater, to make certain the valve
operates freely. Allow several gallons to
ush through the discharge line to an
open drain.
Rapid closing of faucets or solenoid
valves in automatic water using
appliances can cause a banging noise
heard in a water pipe. Strategically
located risers in the water pipe system
or water hammer arresting devices can
be used to minimize the problem.
Inspect the area around the water
heater to ensure a safe operating
environment. Keep water heater
area clear and free from combustible
materials, gasoline, and other
ammable vapors and liquids. Ensure
the unit has not been damaged. If
damage or denting is present, contact
a service personnel to verify proper
operation.
Check for any abnormal sounds during
normal operation of the water heater.
All piping should be checked for gas
and/or water leaks. Refer to page 12
of this manual for instructions on leak
testing.
The air intake and cold water supply
lters should be cleaned monthly. Refer
to the “Housekeeping” section for
further information.
DO NOT operate the water heater if
you feel something is wrong with the
unit.
DO NOT allow children to operate or
otherwise handle the unit.
DANGER: Before
manually operating
the relief valve, make
certain no one will be
exposed to the danger
of the hot
water released by the
valve. The water may
be hot enough to
create a scald hazard.
The water should be
released into a
suitable drain to
prevent injury or
property damage.
DANGER: Hotter
water increases the
potential for Hot
Water Scalds.
DANGER: Failure
to perform the
recommended
Routine Preventative
Maintenance can
harm the proper
operation of this
water heater, which
can cause carbon
monoxide dangers,
excessive hot water
temperatures and
other potentially
hazardous conditions.
Care and cleaning of the water heater.
Routine Preventative Maintenance
NOTICE: If the pressure relief valve on the hot water heater discharges periodically, this may be
due to a problem in the water system. Contact the water supplier or your plumbing contractor
on how to correct this. DO NOT plug the relief valve outlet.
NOTICE: After inspection, maintenance, and/ or cleaning, ensure proper operation by turning on
a hot water faucet.
HOW TO CLEAN THE WATER FILTER:
1. Make sure the unit is OFF and the electrical power supply has been
disconnected.
2. Turn the water supply OFF to the heater.
3. Unscrew the water lter, and slide the lter out.
4. DO NOT tap the lter as it may deform and/or damage the lter.
5. To remove severe dust, use a soft brush and wash with running water.
6. Return the lter to the water heater and screw in the lter.
7. Turn the electrical power supply and cold water supply ON to the water heater
Housekeeping
6 MONTH CLEANING ROUTINE
To prevent water scale, lime or rust deposit buildup and ensure your Eccotemp tankless water heater is running
as eciently as possible it is highly recommended that you clean your Eccotemp tankless water heater every
6 months. To do this we recommend that you use our Eccotemp EZ-Flush System Descaler Kit. For more
information and to purchase please visit us at www.eccotemp.com or call 1-866-356-1992.
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp EL22 seriesEL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp EL22 seriesEL in the language / languages: English as an attachment in your email.

The manual is 2.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info