1.
Instant Heat ON/OFF key
2.
Adjustment Up key
3.
Disengaged pre-set symbol
4.
Ventilation symbol
5.
Temperature ramp.
6.
Current Time, Preset Time,
Heating Time, Run Time
and Diagnostics.
7.
Day selected indicator boxes.
8.
Clock symbol.
9.
Heater operation symbol.
10.
Preset Programme
symbols.
11.
Adjustment Down key.
12.
Programme key.
13.
Set/Programme key.
8
9
10
11
12
13
7
6
5
4
3
2
1
Low Heat
High Heat
701 Series Timer / Modulator With Diagnostic Readout Instructions
Introduction
Your Timer/Modulator offers manual
and programmable control along with
temperature adjustment of your heater.
When the heater is switched on by the
Timer/Modulator in a programmed
mode it will run for 1 hour or for the
duration time that you have selected e.g
Heater on at 0700, duration time of 1 hour,
which means heater will be switched off
automatically at 0800.
C
lock Settings:-
Press and hold
key until the
symbol
begins to flash. Use the
begins to flash. Use the
and
keys to
set correct time. Press and release the
key and the day box will begin to flash.
Use the
and
keys to set the correct
day. Press and release the
key again to
reset the clock to the start of the minute
displayed. This may be used to coincide
with a known time signal.
Please Note:
These adjustments are not possible
when the heater is in operation. To set the
heater’s programmable switch on timer, see
“Setting Program Times”.
S
witching on the Heater
(Manually)
Press the
key and the
symbol will
appear on the display. The heater will
commence its startup cycle. The display
will change to show a default of one hour
heating countdown time. This can be
extended
in increments of 10 minutes,
30 minutes, 1 hour, 1 hour 30 minutes, 2
hours
up to eight hours or to continuous
up to eight hours or to continuous
running operation (shown as C-: -- on
display) by repeatedly pressing the
key
while the heater is in operation. Current
time will be displayed every 5 seconds.
Switching off the Heater
(Manually)
The heater may be switched off at any time
by pressing the
key. The cooling down
cycle will then be initiated.
Adjusting the Temperature
Pressing the
and
keys will alter the
20 segment temperature ramp shown on
the display. This level may be adjusted
at any time and will remain in the
timer memory when the heater is not in
operation.
Diagnostic Readout
With the heater switched on, press and
hold
key until the display shows
“dAtA”. Release key and display then
shows “AF--” and alternatively displays
the current fault code. Each press of
the
key will scroll through the last 5
previously stored fault codes.
Typical fault codes -
10 = Over voltage - Check battery charging system.
11 = Under voltage - Check battery voltage.
12 = Overheating - Check air ducts for obstruction.
52 = Safety time exceeded - Check fuel supply.
For other codes consult your local dealer.
2


Need help? Post your question in this forum.

Forumrules
1

Forum

eberspacher-timer-modulator-701-serie

Reset search

  • Although all the programs are set to "off", the heater still comes on and the only way i can get it to stop is to reduce the temperature.
    I have the "c" symbol permanently in the time display so does this mean the heater is operating continuously? How do I turn continuous off? Submitted on 17-10-2020 at 18:23

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eberspacher Timer Modulator 701 serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eberspacher Timer Modulator 701 serie in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info