701116
17
Zoom out
Zoom in
Previous page
1/29
Next page
17
D
S
GB
F
Electrical system
Electrical lines, switchgear and controllers must be
positioned in the vehicle in such a manner that per-
fect performance under normal operating conditions
is not impaired (e.g. due to the effects of heat,
moisture and similar).
The pilot lamp (incorporated in the control unit)
should be within the diver's field of view or it should
be readily visible without entailing major effort.
The following cable cross-sections between battery
and heater must be maintained to ensure that the
maximum permissible voltage loss in the cables of
0.5 V at 12 V, and 1 V at 24 V rated voltage, is not
exceeded.
Length of the supply cable Plus (L+ red)
and Minus (L- brown), together
< 5 m = cable cross section 2.5 mm
2
5 m 8 m = cable cross section 4 mm
2
If the plus cable is to be connected to the fuse box
(e.g. Cl. 30), then the vehicle's own cable from the
battery to the fuse box must be taken into account
when calculating the total cable length and, if neces-
sary, be newly dimensioned.
Apply contact protection grease to the plug and
earth connections outside the interior space.
Care needs to be taken that the insulation of electric
wiring cannot be damaged due to fraying, kinking,
damage, pinching or the effects of heat.
Electrical plug and earth connections have to be free
of corrosion and tight.
In the case of watertight plugs, plug chambers which
are not used need to be sealed with a blind plug in
a dirt and water tight manner.
Apply contact protection grease to plug and earth
connections which are not used indoors.
In stationary heating mode, electricity from the
vehicles battery is consumed; this electricity
is recharged by the electric generator during
a subsequent ride.
If the travelling time up to the next start of the
heater is as a rule shorter than the preheating time
(short-distance drivers), then the battery needs to
be checked at regular intervals (depending on its
rating) and possibly recharged. This can either be
done out by means of a battery charger or by
covering longer distances in between.
Rule of thumb:
minimum travelling time = preheating time
ATTENTION!
Permissible suction and pressure level
Pressure level from the vehicle's tank to the dosing
pump: a = max. 3 m
Suction level with a pressureless vehicle tank:
b = max. 1 m
Suction level with a vehicle tank in which fuel tapping
produces a vacuum (valve with 0.03 bar in the tank
closure):
b = max. 0.4 m
Manometric lift from the dosing pump
to the
AIRTRONIC
:
c = max. 2 m
ATTENTION!
Check the tank venting.
L
L +
+
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
17


Need help? Post your question in this forum.

Forumrules
1

Forum

eberspacher-airtronic-d2

Reset search

  • 128 11 0000 cannot find what this is red light comes on and has that number and says refer to manual? Submitted on 19-12-2022 at 23:59

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eberspacher AIRTRONIC D2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eberspacher AIRTRONIC D2 in the language / languages: English as an attachment in your email.

The manual is 2,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eberspacher AIRTRONIC D2

Eberspacher AIRTRONIC D2 Usermanual and installation guide - Dutch - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info