To ensure continued performance from your Ebac 6000 the filter should be changed every 3 months.
A red light on the control panel will illuminate when the container is full, an audible alarm will also sound (if activated).
When this occurs water collection stops. When nearly full the indicator will flash a few hours before the container fills and
again the audible alarm will sound. It is advisable to empty the water container if the unit will be unattended for more
than a few hours to ensure the container doesn’t become full and the unit switch off whilst you are away. Once full the
unit will remain off until the container has been emptied and replaced.
To empty, open the water container
access door
6
7
The container can then be removed
and emptied as shown
Replace the container back into the
dehumidifier with the outlet on the
left hand side and gently close the
access door. The dehumidifier will
also switch itself off while the
container is removed.
Your Ebac 6000 has a filter system to remove dust from the air. This requires cleaning and we recommend that the
filter(s) be inspected every 4 weeks. Failure to do so will reduce the efficiency of your Ebac 6000. To clean, proceed
as follows:
Remove the filter(s) by removing the
filter covers
Remove the filter and clean with a
vacuum cleaner on a low power.
To refit, place the filter material back
into the holder(s) and replace onto the
unit
Boost Control
Ebac 6000 models have a boost control that increases performance of the unit in damp conditions. When activated
this increases the fan speed and operating mode to maximum for eight hours. This is particularly useful for periods of
high humidity such as drying laundry indoors or just after bathing. After this time the unit will return to the settings
you had prior to activation.
Fan only / Air cleaning mode
Ebac 6000 models are fitted with a fan only/air cleaning option. Select this mode if you want the fan to run all the time
without the dehumidifier operating. This is particularly useful during the summer to provide a fan facility and for air
filtration.
Audible container full alarm
Your Ebac 6000 is fitted with an audible alarm which beeps approximately every minute once the container is full. This
can be activated by pressing down the MODE button for 5 seconds until a beep is heard. You can de-activate this at
any time by again pressing down the MODE button for 5 seconds until a beep is heard.
Fan speed control
You may wish to change the fan speed of your Ebac from time to time. Using the Normal setting will remove more
moisture from the air compared to the Quiet setting thereby improving efficiency. When switched on your
dehumidifier will default to Normal.
Setting Function
Light not illuminated Normal setting
Light illuminated Quiet setting
Your Ebac 6000 will collect excess moisture either as condensed water or ice on the heat exchanger located inside the
unit. Any accumulation of ice is cleared periodically. Your Ebac 6000 incorporates a Defrost System which selects the
correct defrost mode for your home. This maximises the efficiency of the unit at temperatures between 3°C / 37°F and
35°C / 95°F
Setting the controls Emptying the water container
Cleaning the filter
4


Need help? Post your question in this forum.

Forumrules
1

Forum

ebac-6200

Reset search

  • The back of my Ebac 6200 Dehumidifier is all iced up ! Submitted on 9-2-2020 at 18:24

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ebac 6200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ebac 6200 in the language / languages: English as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info