5. CONFIGURATION OF THE ALARM REGISTERS
5.1 Sensor-1 monitoring
5.1.1 Sensor-1 as alarm contact
EasyAlarm
®
auto-detects a Plug&Protect-sensor and starts its monitoring if the system is armed. You can define the
behaviour for sensor-1 as following:
Example: A normally closed contact shall trigger an un-delayed alarm with a hands-free-connection independent from
position of the selection switch.
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 5 6 #. #.. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 1. 0 0 0. 1. 1. .
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0: off 0:off 0: Listening-in I / II / III 00: inactive
1: on 1:on 1: Hands-free 0 0 0 01: Normally open contact
0: enabled 10: Plug&Protect (auto-detected at power-on)
1: disabled input-2 is open => Normally open monitoring
input-2 is closed => Normally closed monitoring
5. Press key #. . 11: Normally closed contact
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
5.1.2 Sensor-1 for presence verification
You can also use sensor-1 to monitor missing activity (i.e. no motion detected within a certain period) => Alarm message:
„Emergency call due to sensor-1“. Therefore you have to activate time-out as below.
5.1.2.1 How to program presence verification time-out
Time-out for presence verification is factory set to 24h. If there is no activation within this period, an alarm is triggered
after a pre warning period of 10 minutes (this period is indicated with a periodical loud beep tone).
1. Shift function switch to PROG
2. Enter *. 9. 7. 1. 3 6 7 #. #. .
Current register value <n> will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 4. Otherwise modify register with *. New value <n> #..
The new register value <n> will be announced
4. Shift function switch to OFF
<n> Explanation
0 Presence verification is switched off (=Factory setting)
6..255 Time-out in steps of 10 min. (min. 60min, max. 42.5h) => For example: n=144 (144*10min = 24 h)
5.1.3 Sensor-1 as entry-detector (Gong function)
A sensor-1 activity can also be signalled locally (Gong-function) according to the following procedure:
Example: Sensor-1 shall greet an incoming person with the pre-recorded individual message only on position I.
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 3 1 #. #...
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 0. 0 1 1. 1. 0. .
Unused Gong on.. Gong-type
000: I / II / III 00: Gong
0 1 1 01: --
0: enabled 10: Individual message
1: disabled 11: Beep loud
5. Press key #. .
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
Factory default for sensor
-
1 monitoring
00 0 000 10, => un-delayed alarm in listening-in
connection only on all positions I/II/III
=> connector type: auto-type (plug&protect)
Factory default for gong
-
function sensor
-
1
000 111 00
Note:
If you do not want to
trigger an alarm on
position I you have to
disable alarm according to
section 5.1.1
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EasyAlarm CONTROL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EasyAlarm CONTROL in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EasyAlarm CONTROL

EasyAlarm CONTROL User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info