6.3 Barometric Trend Pointer (A1)
The trend pointer displayed on the LCD (A1) indicates the trend of the Barometric
pressure.
7. Thermometer
7.1 RF Transmission Procedure:
The main unit automatically starts receiving transmission from outdoor thermo sensor
for outdoor temperature after batteries are inserted.
The thermo sensor unit will automatically transmit temperature signal to the main unit
after batteries inserted.
For having more than one external transmitter (Maximum3), select the Channel, CH1,
CH2 or CH3 to ensure each sensor is transmitting difference channel before inserting
batteries. The channel select switch (D3) is at the back of the thermo sensor.
If main unit failed to receive transmission from outdoor thermo sensor in rst 3 minutes
after the batteries inserted (“- - . –”display on the LCD), hold “Channel” button (B8) for
3 seconds to receive transmission manually. RF icon “
” ashes on the LCD
Note: Buttons (except “Channel” & “Lightbuttons) will not function while scanning for
thermo sensor’s signal unless they are well received or stopped manually.
Indicating the barometric
pressure trend is rising
Indicating the barometric
pressure trend is steady
Indicating the barometric
pressure trend is falling
ENGLISH 6 ENGLISH 7
7.2 Temperature & Humidity
(1) Outdoor Temperature--- Channel Selection
Press “CHANNEL” button (B8) to view the 3 Channel’s temperature. The sequence is
shown as follow:
PRESS “CHANNEL” button > PRESS “CHANNEL” button > PRESS “CHANNEL” button
When viewing the record on CHANNEL 1 or 2, or 3, hold “CHANNEL” button (B8) for 3
seconds to cancel the record on this channel manually, and receive the transmission
from channels automatically again.
OUT OUT
OUT
Display the three
channels alternatively
(2) Outdoor Temperature Trend
The trend pointer (A6) displayed on the LCD indicates the trend of the outdoor
temperature.
(3) Celsius / Fahrenheit
Press “°C /°F” button (B4) to select Indoor/Outdoor Temperature in Celsius mode or
Fahrenheit mode.
If the temperature is out of the measurable range, LL.L (beyond the minimum
temperature) or HH.H (beyond the maximum temperature) will be shown on the LCD.
(4) Maximum / Minimum Temperature & Indoor Humidity Recording Function:
Press “MAX/MIN” button (B3) to show the maximum recorded Indoor /Outdoor
Temperature and Indoor Humidity. “ ” is shown on the LCD
Press “MAX/MIN” button again to show the minimum recorded Indoor/Outdoor
Temperature and Indoor Humidity. “ ” is shown on the LCD.
Hold “MAX/MIN” button (B3) for 3 seconds to clear the recorded maximum and
minimum reading.
8. Time and Alarm Setting
8.1 Radio Controlled Clock:
After batteries inserted and main unit nishes receiving the transmissions from outdoor
thermo sensor, the clock automatically starts to scan the DCF time signal. Radio
Control Icon “ ” (A9) ashes on the LCD.
The clock automatically scans the time signal at 3.00 a.m. every day to maintain
accurate timing. If reception fail, scanning stops (“ ” on LCD disappear) and repeats
again at 4.00 a.m. 5.00a.m. and 6.00a.m.
The clock can be set to scan the time signal manually by holding “ ” button (B4) for 3
seconds. Each reception takes about 5 minutes. If receptions fail, scanning stops.
(“ ” on LCD disappear) and repeats again at next hour. E.g. scanning failed at
8:20a.m. It will scan again at 9:00a.m.
(A9) ashes, Indicating
now is receiving DCF signal
(A9) turns on,Indicating
signal received successfully
(A9) disappear, Indicating
signal reception failed
Indicating the outdoor
temp. is rising
Indicating the outdoor
temp. is steady
Indicating the outdoor
temp. is falling
Downloaded from www.vandenborre.be
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ea2 LABS AL803 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ea2 LABS AL803 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info