1514
The unit will shut down automatically when
NIGHT mode is running for more than 12
hours.
Note: the night mode is not available while the
machine is operating in AUTO, Fan (ventilation) or
Dehumidication mode.
Note: In night mode, the display will
automatically dim after a few seconds. Press any
key to reactive the control panel.
Self-diagnosis
This machine is equipped with self-diagnosis
software. If the device is not working, the LCD
display will show “E1” or “E2”. When this occurs,
please contact your point of purchase.
All the above functions can also be performed with
the supplied remote control. This remote control
requires a cell battery CR2032 to operate.
Note:
•To prolong the lifespan of the compressor, please
wait at least 3 minutes before re-switching on the
device after switching o.
The cooling system will switch o if the ambient
temperature is lower than the set one. However, the
ventilation keeps operating on the set level. If the
ambient temperature rises above the selected level,
the cooling will return to work.
Adjusting the ventilation speed
Press the SPEED button to choose the
ventilation speed you prefer: high, medium
or low. The indicator of high, medium or low
ventilation will illuminate.
Setting the timer
By pressing the TIMER button without using the
other functions, you can activate a start delay.
For example, if you set the timer to ‘2’, the unit
will automatically start after 2 hours.
Press the TIMER button to set a time-out (1 to
24 hours, the timer indicator will illuminate).
When the set time has been reached, the
machine will turn o automatically. The LCD
display will show the hour(s) you set as you
press the TIMER button.
Night mode
When pressing the NIGHT mode button in
cooling mode, the set temperature will increase
with 1⁰C after one hour, another 1⁰C after two
hours and then stays at that temperature.
In NIGHT mode, the ventilation will remain
at low speed. By pressing the NIGHT mode
button again, the temperature and ventilation
speed will return to the previous settings.
1
3
EN
1
2
1
2
Drainage
During the process of cooling, some water will be
extracted from the air into the unit. If the reservoir
is full, both of the compressor and motor will
switch o and the units will buzz (press any button
to turn it o). The WATER FULL indicator will ash
to show you.In this case, please empty the water by
following the steps below:
Turn o the air conditioner and avoid moving it
when the water tank is full.
Put a container (a water tray for example)
underneath the drain hole.
Remove the drain knob & rubber plug from the
drain hole and allow the water to drain out.
When the container is almost full, close the
drain hole with the rubber plug and empty the
water tray.
Repeat until the unit is fully empty.
Replace the rubber plug andrmly tighten the
drain knob.
Switch on the device - the full water indicator
should not be ashing anymore.
If you wish to operate the unit without the need to
empty the water tank (continuous drainage), please
follow these steps:
Remove the drain knob and rubber plug and
retain for future use.
Connect the drain tube supplied to the water
outlet as shown and locate the other end into a
1
2
3
4
5
6
7
drain.
The drain tube may be extended by adding an
extension tube and using a suitable connector.
Note:
• The drain must be at or below the outlet level.
The FULL WATER indicator will be disabled in this
mode of drainage.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Duux DXMA05 Blizzard at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Duux DXMA05 Blizzard in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 9.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info