612067
124
Zoom out
Zoom in
Previous page
1/140
Next page
Error and information messages
122
Operating instructions 906 - Version 00.0 - 05/2014
4201 Internal CF card defective Switch the machine off and on again
Retrofit/replace controller
5301 Program cannot be sewn Copy program to DAC
6551
6554
6651
6653
6751
6761
Error in upper part position/AD
converter/process error
Internal error
Switch the machine off and on again
Software update
Notify DA Service
6952 Stepper motor driver error
Internal error
Switch the machine off and on again
Software update
Notify DA Service
Communication
7801 Control panel interface communication
Cable fault
•Cable
Switch the machine off and on again
Software update
Notify DA Service
8151
8156
8159
IDMA error
Fault
Controller defective
Switch the machine off and on again
Replace the controller
8152
8154
IDMA error
Internal error
Switch the machine off and on again
Software update
Notify DA Service
8252
8257
8258
8256
8254
ADSP Boot/Xilinx Boot/ Boot error
Fault
Switch the machine off and on again
8351 Test pins error Switch the machine off and on again
Software update
Notify DA Service
9601 Stop while sewing on the contour
Continue sewing?
OK button =
Continue sewing
ESC button =
Cancel sewing
9700 Bobbin change flap not closed Close the bobbin change flap
9701 Parallel clamps not lowered Remove obstacles
Adjust sensors
9900 Incorrect machine parameter Initialize the data
9901 Incorrect sequences Initialize the data
9902 Incorrect program parameter Initialize the data
Error
code
Description Remedy
124


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 906 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 906 in the language / languages: English as an attachment in your email.

The manual is 8,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 906

Durkopp Adler 906 User Manual - German - 140 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info