Decommissioning
Operating manual 806N Version 00.0 - 12/2012 103
7 Decommissioning
A number of activities must be performed if the machine is to be shut down
for a longer period of time or completely decommissioned.
Decommission the machine as follows:
1. Switch off the main power switch under the sewing material support.
2. Turn the compressed air shut-off valve, at the right next to the main
power switch, to the right in the horizontal position.
3. Unplug the power plug.
4. Disconnect the pneumatic connection.
5. Remove residual oil from the oil pan under the sewing material sup-
port using a cloth.
6. Cover the operating terminal to protect it from soiling.
7. Cover the controller at the edge folding station to protect it from soil-
ing.
8. Cover the entire machine if possible to protect it from soiling and dam-
age.
Observe the necessary safety precautions for transport, Section 8
Packing, transportation.
Risk of injury due to a lack of care.
A lack of care or a lack of sufficient technical
knowledge when decommissioning the machine
can result in serious injuries.
ONLY clean the machine when it is switched off.
Avoid contact with oil residues.
Allow ONLY trained personnel to disconnect the
machine.
WARNING
105


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 806N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 806N in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 806N

Durkopp Adler 806N User Manual - German - 114 pages

Durkopp Adler 806N User Manual - French - 114 pages

Durkopp Adler 806N User Manual - Spanish - 114 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info