2. Operation
Turn main switch off!
- Risk of Injury -
when threading
when replacing sewing tools e.g. needle
when cleaning
when leaving the work place unattended
by maintenance work
2.1 Replacing the material guide rail by
primary seams
Turn main switch off!
- Risk of Injury! -
Removing
Place valve lever 1 in the down position.
Lift the guide piston 2 with its two rollers 9 and
8 out of the rail 3.
Pull the rail 3 out of the needle area from the
front.
Release the left and right clamp lever 7.
Remove the rail after lifting the clamp piston 6
and place in the mounting at the left on the
covering hood.
Inserting
The insertion of the rail is conducted in the
reverse order.
When tightening the clamp lever 7 care should
be taken to see that the pin 5 of the clamp
piston 6 snap into the hole 4 of the rail.
The roller 8 of the guide piston and the roller_9
for the thread trimmer must be lowered into the
groove on the rail. Place the valve lever 1 up
again. Otherwise the display *Schiene* will
appear. - A starting of the sewing unit is then
not possible.
2
3
7
6
5
4
1
2
1
9
8
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 744-122 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 744-122 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 744-122

Durkopp Adler 744-122 User Manual - German - 8 pages

Durkopp Adler 744-122 User Manual - French - 8 pages

Durkopp Adler 744-122 User Manual - Spanish - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info