5.6 Attachment
Caution Risk of Injury !
Pull the mains plug.
The attachment of the upper thread catcher may only be
conducted with the machine turned off and only by trained
skilled personnel.
5.6.1 Pre-assembling the Wiring Distributor
The designation numbers affixed to the cables and position numbers in these
instructions are indentical with the cable numbers in the enclosed hook-up diagram
558 10296 and in the circuit diagram 558 10295.
Lay the cables 2 and 3 through the holder tube 12.
Connect the cores of the cables to the two outside terminals (1 and 4) of the
switches b1 and b2.
Fasten the switches b1 and b2 to angle 13.
Lay the cables 1 and 4 through the holder tube 11.
Connect the cores of cable 1 to magnet plug 10.
The terminal with the ground symbol remains free.
Connect the cores of the cable 4 at switch b3 to the terminals "Normally open" (3)
and "Common" (1).
Pull the cable brackets of cable 7 off of the connects in the wiring distributor L1.
Since the button b5 is already soldered on the freed cable end must be fed through
the holder tube 11 from above.
Push the cable brackets back onto the contacts (1 and 5).
Connect the cores of cable 6 to the two outside terminals (1 and 4) of the switch b4.
97
95


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 558 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 558 in the language / languages: English as an attachment in your email.

The manual is 6,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 558

Durkopp Adler 558 User Manual - German - 102 pages

Durkopp Adler 558 User Manual - French - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info