613262
15
Zoom out
Zoom in
Previous page
1/15
Next page
Checking the oil level in the oil reservoir of the maintenance unit
The oil level in oil reservoir 5 should not drop below the groove
marking.
If necessary, fill oil up to the groove marking.
For this completely shut off the compressed air by turning the knob
1 to the left.
To fill screw out the oil fill screw 3.
After filling with oil set an operating pressure of 6 bar by pulling up
the knob 1 and turning it to the right.
The set operating pressure can be seen on the pressure gauge 4.
Checking the oil flow of the oil mister
Under operating pressure a drop of oil should drip out of the tube
under viewing glass 5 after about 10 work cycles.
Regulate the strength of the thus created oil mist with the setting
screw 2.
1
2
3
4
5
17
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 550-12-12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 550-12-12 in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 550-12-12

Durkopp Adler 550-12-12 User Manual - German - 15 pages

Durkopp Adler 550-12-12 User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info