8.6.3 Machine errors
Error Description Possible causes Troubleshooting
code
1051 Sewing motor timeout · Cable to motor faulty
· Reference switch faulty
. Sewing motor faulty
. Mechanics rough-running
· Check cable
· Check reference switch
. Check sewing motor
. Check mechanics
1052 Sewing motor
overcurrent
· Cable to motor faulty
· Sewing motor faulty
· Control faulty
. Software not compatible to the
control unit version (A/Bxx.x)
· Check cable
· Check sewing motor
· Check control
. Check the serial number of the
DAC III control unit
1
, if necessary
load the correct software version.
1053 Sewing motor
overvoltage
- Mains voltage too high
- Check mains voltage
1055 Sewing motor
overload
· Sewing motor is blocked /
rough running
· Sewing motor faulty
· Control faulty
· Remove cause of block / rough
running
· Check sewing motor
· Check control
1056 Sewing motor
overheated
· Sewing motor rough running
· Sewing motor faulty
· Control faulty
· Remove cause of rough running
· Check sewing motor
· Check control
1058
1059
Motor speed
(inverted)
Sewing motor faulty
Check sewing motor
1062 Sewing motor IDMA
autoincrement
Breakdown
Switch machine off and on again
1302 Sewing motor power
source error
-Plug for sewing motor
not plugged in
-Plug for incremental
sensor not plugged in
- Connect the plug for the sewing
motor
- Connect the plug for the
incremental sensor
1342
-
1344
Sewing motor error Internal error
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
2101 Step motor X-axis
timeout referencing
· Cable to reference switch faulty
· Reference switch faulty
. Step motor faulty
. Mechanics rough-running
· Check cable
· Check reference switch
. Check step motor
. Check mechanics
2152 Step motor X-axis
overcurrent
· Step motor X-axis faulty
· Control faulty
· Check step motor X -axis
· Check control
2153 Step motor X-axis
overcurrent
Mains voltage too high
Check mains voltage
2156 Step motor X-axis
overheated
· Step motor X-axis
rough running
· Step motor X-axis faulty
· Control faulty
· Remove cause of rough running
· Check step motor X -axis
· Check control
2162 Step motor Y-axis
IDMA autoincrement
Breakdown
Switch machine off and on again
1
Serial numbers 0302-00101 ... 0307-00643: the control unit should be used with an Axx.x-Version
Serial numbers 0307-00644 and higher: the control unit should be used with an Bxx.x-Version
1
81
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 530 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 530 in the language / languages: English as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 530

Durkopp Adler 530 User Manual - German - 98 pages

Durkopp Adler 530 User Manual - French - 98 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info