613287
90
Zoom out
Zoom in
Previous page
1/102
Next page
Fehler- Beschreibung Mögliche Ursache Fehlerbehebung
code
7551
-
7559
Kommunikation
Bedienfeldschnitt-
stelle
Interner Fehler
- Maschine aus-und wieder
einschalten
- Softwareupdate
- Rückmeldung an DA-Service
7556
7557
Kommunikation
Bedienfeldschnitt-
stelle
- Leitungsstörung
- Kabel Bedienfeld-
schnittstelle defekt
- Störquelle ausschalten
- Kabel überprüfen
7700 Protokoll: Maxanzahl
Wiederholungen
- Leitungsstörung
- Kabel Testschnittstelle
defekt
- Störquelle ausschalten
- Kabel überprüfen
7701 Fehler Protokoll Interner Fehler
- Maschine aus-und wieder
einschalten
- Softwareupdate
- Rückmeldung an DA-Service
8351
8700
8702
8800
-
8806
8890
8891
Fehler Testpins
/Tastensimulation
/Signal-/
Ereignisbearbeitung
/Memory-Wrapper /
Liste Funktionen
Interner Fehler
- Maschine aus-und wieder
einschalten
- Softwareupdate
- Rückmeldung an DA-Service
9100
-
9105
9200
9201
9900
9902
9903
9905
Fehler
Nähmusterverwaltung
/ Nähmusterprogramm
/Nähmusterfreigabe /
Einrichtung
/Tastenbearbeitung
/Speicher
Meldungsausgabe
Interner Fehler - Maschine aus-und wieder
einschalten
- Softwareupdate
- Rückmeldung an DA-Service
Falls der Fehler 9100 wiederholt
auftritt, über das Menü
Initialisierung die
Nähmusterprogramme und
Sequenzen zurücksetzen
(vgl. Seite 60).
Falls ein Fehler auftreten sollte, kann die entsprechende Einheit über
das Menü Service/Multitest auf ihre korrekte Funktion geprüft werden
(vgl. Seite 49). Das Menü Service kann über die Technikerebene sowie
bei Einschalten der Maschine durch drücken der Taste F bei
Erscheinen des DA Logos erreicht werden (Codeeingabe 25483).
86
90


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 511 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 511 in the language / languages: German as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 511

Durkopp Adler 511 User Manual - English - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info