613288
88
Zoom out
Zoom in
Previous page
1/103
Next page
Error- Description Possible cause Troubleshooting
code
7701 Error Protocol Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8151
8156
-
8159
Error IDMA - Failure
- Control faulty
- Switch the sewing machine off
and on again
- Replace control
8152
-
8154
8251
8255
Error IDMA / Booting
ADSP / Booting
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
8252
8257
8258
/
8253
8256
8254
Booting ADSP /
Booting XILINX /
Booting
Failure
- Switch the sewing machine off
and on again
8351
8700
8702
8800
-
8806
8890
8891
Error Testpins / Key
simulation / Signals /
Event processing /
Memory-Wrapper /
List of functions
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
9100
-
9105
9200
9201
9900
9902
9903
9905
Error seam pattern
administration / seam
pattern program /
seam pattern release /
Equipment / Key
processing / Memory
Output Message
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
If the error 9100 appears
repeatedly, go through the
initialization menu and reset the
seam pattern programs and
sequences (compare to page 62).
9906 Error monitoring
switch clamping foot
- Switch faulty
- Cable faulty
- Distance switch-lug
too big
- Check the switch
- Check the cable
- Check the clearance
After troubleshooting set the
machine parameters to the factory
settings, so that the switch can be
recognized again (compare to page
62).
Should an error occurs, the corresponding component can be checked
over the menu service/multi-test for its correct function (compare to
page 49). The service menu can be reached by switching to the
”Technician mode" or by pressing the key F when switching on the
machine (enter the code number “25483").
86
88


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 510 in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 510

Durkopp Adler 510 User Manual - German - 103 pages

Durkopp Adler 510 User Manual - French - 103 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info