613288
83
Zoom out
Zoom in
Previous page
1/103
Next page
8.6.3 Machine faults (DAC III)
Error- Description Possible cause Troubleshooting
code
1051 Sewing motor timeout - Cable to sewing motor-
reference switch faulty
- Reference switch faulty
- Sewing motor faulty
- Mechanical parts
rough-running
- Check cable
- Check reference switch
Check sewing motor
- Check the mechanical parts
1052 Sewing motor
overcurrent
- Sewing motor cable faulty
- Sewing motor faulty
- Control faulty
- Software not compatible
to the control unit version
(A/Bxx.x)
- Check sewing motor cable
- Check sewing motor
- Check control
- Check the serial number of the
DAC III control unit
1
, if necessary
load the correct software version.
1053 Sewing motor
overvoltage
Mains voltage too high
Check the mains voltage
1055 Sewing motor
overload
- Sewing motor blocked
/rough-running
- Sewing motor faulty
- Control faulty
- Eliminate blocking/rough-running
- Check sewing motor
- Check control
1056 Sewing motor
overheat
- Sewing motor rough-running
- Sewing motor faulty
- Control faulty
- Eliminate rough-running
- Check sewing motor
- Check control
1058
1059
Sewing motor speed
(inverted)
Sewing motor faulty
Check sewing motor
1062 Sewing motor IDMA
Autoincrement
Failure
Switch the sewing machine off
and on again
1302 Sewing motor power
source error
- Plug for sewing motor
not plugged in
- Plug for incremental
sensor not plugged in
- Connect the plug for the sewing
motor
- Connect the plug for the
incremental sensor
1342
1344
Sewing motor failure Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
2101 Step motor X-Axis
Timeout Referencing
- Cable to
reference switch faulty
- Reference switch faulty
- Step motor faulty
Mechanical part
rough-running
- Check cable
- Check reference switch
- Check step motor
- Check the mechanical parts
2152 Step motor X-Axis
overcurrent
- Step motor X-Axis
faulty
- Control faulty
- Check step motor X-Axis
- Check control
2153 Step motor X-Axis
overvoltage
Mains voltage too high Check the mains voltage
2156 Step motor X-Axis
overheat
- Step motor X-Axis
rough-running
- Step motor X-Axis
faulty
- Control faulty
- Eliminate rough-running
- Check step motor X-Axis
- Check control
2162 Step motor X-Axis
IDMA Autoincrement
Failure Switch the sewing machine off
and on again
1
Serial numbers 0302-00101 ... 0307-00643: the control unit should be used with an Axx.x-Version
Serial numbers 0307-00644 and higher: the control unit should be used with an Bxx.x-Version
1
81
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 510 in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 510

Durkopp Adler 510 User Manual - German - 103 pages

Durkopp Adler 510 User Manual - French - 103 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info