4.2 Lubrication
For lubrication of the machine use only
ESSO SP-NK 10
lubricating oil.
SP-NK 10 is available from
DÜRKOPP ADLER AG
sales offices.
Check the oil level in the oil reservoir of the oil mister
The run of the barrel shuttle is lubricated and cooled by compressed
air enhanced with oil from the oil mister.
The oil level in the oil reservoir 5 may not fall below the groove
marking.
If necessary top up the oil to the groove marking.
For this shut off the compressed air completely by turning the
knob 1 to the left.
For topping up screw out the oil filler screw 4.
After topping up set the operating pressure at 6 bar by pulling up
the knob 1 and turning to the right.
The set operating pressure can be seen on the pressure gauge 2.
Check the feed quantity of the oil mister weekly
Under operating pressure a drop of oil should drip out of the pipe
under the viewing glass 5 after every 2 to 3 work cycles.
Regulate the strength of the thus created oil mist at the setting
screw 3.
3
4
5
1
2
17
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 506 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 506 in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 506

Durkopp Adler 506 User Manual - German - 22 pages

Durkopp Adler 506 User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info