Operating manual 100-69 version 00.0 - 05/2013
68
3. Check the configuration of the connections at the switch element and
change the connections according to the existing mains voltage
(see wiring diagram).
4. Attach the cover again and fasten the screw.
5. Connect the mains plug.
6.4.4 Checking the nominal voltage of the vacuum device
The adaptation to the local mains voltage has to be done at the terminal
strip in control box (1). This adaptation may only be carried out by qualified
electricians.
Fig. 56: Nominal voltage vacuum device
1. Screw off the cover of the safety switch (1).
2. Check the arrangement of the connections to the safety switch and if
necessary, change the connections. (see wiring diagram)
3. If necessary, change the connections according to the local mains volt-
age.
4. Screw on the safety switch cover (1) again.
6.4.5 Direction of rotation of the sewing motor and the vacuum
blower
The sewing unit is equipped with the latest step motor technology. A check
of the direction of rotation of the sewing motor is not required because it is
automatically set by the control.
The direction of rotation of the vacuum blower can be inverted by
exchanging the phase (plug).
(1) - Cover of safety switch
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 100-69 Beisler at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 100-69 Beisler in the language / languages: English as an attachment in your email.

The manual is 6,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 100-69 Beisler

Durkopp Adler 100-69 Beisler User Manual - German - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info