12
Setting the Temperature Control
The unit has two separate temperature zones.
The temperature of both zones can be set
between 5ºC and 22ºC (41ºF and 72ºF). The
LOWER/RIGHT temperature zone is ideal for
storing white and red wine at a setting of 13°C
to 22°C (55°F to 72°F). The UPPER/LEFT
temperature zone is suitable for storing
champagne and white wine at a setting of 5°C
to 13°C (41°F to 55°F).
When the unit is plugged in for the first time, the
unit will power up automatically to the preset
defaults. The preset temperature at the factory
for UPPER/LEFT temperature zone is 10ºC
(50ºF) and for LOWER/RIGHT temperature
zone is 16ºC (60ºF).
You can press the left side UP and DOWN keys
to control the internal temperature of the
UPPER/LEFT temperature zone and press the
right side UP and DOWN keys to control the
internal temperature of the LOWER/RIGHT
temperature zone. When you press the two
keys at the first time, the display will show the
last temperature set previously.
IMPORTANT: The temperature set for the
LOWER temperature zone must always be just
as high or higher than that in the UPPER
temperature zone. For optimal performance, the
set temperature of the two zones should differ
by at least 4°C.
The temperature that you desire to set will
increase 1ºC or 1ºF if you press the UP mark
once, on the contrary the temperature will
decrease 1ºC or 1ºF if you press the DOWN
mark once. The display flashes while you make
the setting.
After the temperature has been set, the display
shows the current inner temperature of the
particular temperature zone.
To view the set temperature at any time, press
the UP or DOWN key, the set temperature will
temporarily flash in the display for 5 seconds.
Then the display shows the current inner
temperature again.
USE AND CONTROL THREE ZONE
The Controls of Your Unit
Upper Control Unit
Lower Control Unit
POWER
To turn the appliance on/off, press and hold the
key for 5 seconds until themperature display lights
up or goes out.
NOTE: Pressing the key once can switch off the
audible alarm when the alarm is on.
LIGHT
Used to turn the inner light on/off.
UP
Used to increase (warm) the set temperature by 1°C
or 1ºF.
DOWN
Used to decrease (cool) the set temperature by 1°C
or 1ºF.
Display
Display the digital temperature and service
indicators. is for UPPER temperature zone, is
for MIDDLE temperature zone and is for LOWER
temperature zone.
Indicator Light
The indicator light is located at the right lower corner
of the display. The indicator light will be on when the
multi-key function is selected. To perform the multi-
key function, press and hold the first key, then press
the rest key for at least 5 seconds and then release
all the keys.
ºF/ºC Selector
Select the temperature display setting in Fahrenheit
or Celsius degree. To change the temperature from
Fahrenheit to Celsius or from Celsius to Fahrenheit,
press and hold the LIGHT key for 5 seconds.
Setting the Temperature Control
The unit has three temperature zones. The
temperature of all zones can be set separately.
The temperature settings of UPPER
temperature zone are adjustable with the range
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dunavox DAU-17.57DB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dunavox DAU-17.57DB in the language / languages: English as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info