FULLY INTERGRATED BUILT-IN-COLUMN
INSTRUCTIONS
The unit door seals the installed unit almost
completely, so an air vent must be provided in the
base of the housing. Warmed air must be conducted
via the ventilation shaft to the rear wall of the
housing and then expelled upwards. The ventilation
channels should measure at least 200 square
centimeters in cross-section.
A (mm)
B (mm)
C (mm)
45cm H
444
455
450
60cm H
584
595
590
88cm H
874
885
874-880
122cm H
1223
1234
1223-1230
177cm H
1773
1784
1773-1780
Remark: The dimension A does not include the
adjustable legs and the units are permitted to be
installed without the adjustable legs.
WARNING: To ensure the proper functioning of the
appliance, air vents should never be blocked or
covered.
BUILT-IN CABINETRY INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille. And be sure the door will open and
close properly in the chosen location.
A (mm)
B (mm)
C (mm)
D (mm)
100
1480
550
1476
570
125
1772
550
1768
570
170
1772
660
1768
680
ELECTRICAL CONNECTION
WARNING: Improper use of the grounded plug
can result in the risk of electrical shock. If the power
cord is damaged, have it replaced by a qualified
electrician or an authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with
local and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Connect this appliance to a separate at least 13A
circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it
is advisable to install a residual current device (RCD)
with a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is
grounded correctly.
Note: In locations where there is frequent lightning,
it is advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dunavox DAU-17.57DB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dunavox DAU-17.57DB in the language / languages: English as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info